Estimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria

نویسنده

  • A. A. Adewale
چکیده

Background: One of the means of assessing dose to pa ents from Computed tomography (CT) procedure is through the determina on of the skin entrance dose (ESD) with the apprecia on of the concern that ocular exposure effects from CT scan includes possible induc on of cancer and cataract. Due to the rela vely more recent introduc on of CT scans, li le work has been done in this area in the country including exposure dose on the lens of the eyes of pa ents undergoing Cranial Computed Tomography (C‐CT). Materials and Methods: The Entrance Surface Dose (ESD) to the lens of eyes of 26 pa ents who had cranial CT procedures at a University Teaching Hospital in Ile‐Ife, Nigeria has been determined in order to assess the level of radia on protec on compliance and op miza on of radia on safety at the hospital. Results: Results indicate that the doses to the pa ents ranged between 17.13 mGy and 51.98 mGy within the period under study. The average doses obtained for the pediatric pa ents (1.5‐18 yrs), young adults (19‐49 yrs) and adults (≥50 yrs) were 31.14 ±11.02 mGy, 41.81±12.60 mGy and 31.97 ± 11.31 mGy respec vely. The mean dose obtained in this study was lower than threshold for lens damage, therefore the dose recorded in this study is clinically safe. Conclusion: This study represents a requisite pedestal on the need for a na on‐wide evalua on and inves ga on of op miza on of procedures in radiological examina ons with a view to establishing a na onal dosimetry protocol and reference dose level or guidance level in the country.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria

Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...

متن کامل

Radiation dose to the thyroid, eyes and parotid glands of patients undergoing intra-oral radiographic procedures in a teaching hospital in Ibadan, Oyo state Nigeria

Background: Intraoral radiographs are believed to deliver low doses to patients, thus little work has been done in this regards. Considering the increment in the number of patients reporting for the examination and the probability of delayed somatic effects for accumulated low doses of X-irradiation, it is expedient to determine the doses to three critical organs eye, thyroid and parotid that a...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

Assessment of Radiation Dose to the Lens of the Eye and Thyroid of Patients Undergoing Head and Neck Computed Tomography at Five Hospitals in Mashhad, Iran

Introduction: In recent years, the number of computed tomography (CT) scans, which is a high-dose technique, has increased significantly. Head and neck CT is performed frequently and thyroid, particularly in children, has always been considered a sensitive organ. In recent years, radiobiologists and health physicists have been more concerned about the safety of lenses of the eyes, as cataract i...

متن کامل

Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms

Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017