Adiabatic Magnetization Preparation Pulse for T2-contrast at 7 Tesla

نویسندگان

  • P. Balchandani
  • D. Spielman
چکیده

Introduction: High-resolution MRI at 7T has the potential to provide tremendous improvement in the diagnosis and treatment of a wide range of neurological diseases. High-resolution T2-weighted sequences are sensitive for assessing subtle structural abnormalities associated with many of these diseases [1]. Unfortunately, conventional T2-weighted sequences, such as Fast Spin Echo (FSE), utilize a train of high flip-angle Shinnar LeRoux (SLR) [2] refocusing pulses that are very susceptible to the severe B1 inhomogeneity and SAR limitations observed at 7T. We propose an alternative adiabatic magnetization preparation (AMP) technique to obtain B1-insensitive T2-contrast at 7T. A BIR-4 pulse [3,4] with a flip angle of 0° with delays inserted between segments is used to introduce T2 decay. Such a pulse was previously described for use in zero or double quantum filters [5] and T2 magnetization preparation at 3T [6]. We use the adiabatic SLR technique described in [7] to generate the BIR-4 segments so that the peak RF amplitude at adiabatic threshold is minimized and a greater range of adiabaticity is achieved. An AMP pulse was designed for use at 7T and validated with phantom and in vivo experiments. Method: The adiabatic SLR algorithm [7] was used to create an adiabatic full passage pulse with the following pulse parameters: 5 kHz bandwidth, 14ms duration and peak B1 value of 11.46μT. The pulse was divided into adiabatic half passage segments and used to compose a BIR-4 pulse with a 0° rotation. Symmetric time delays were introduced between half passage segments 1 & 2 and 3 & 4 to create the final AMP pulse with a total duration of 53ms. Amplitude and phase waveforms for the AMP pulse are shown in Figs. 1 A and B. Simulations were performed to test the B1insensitivity of the AMP pulse. The profile of the AMP pulse followed by a 90° linear-phase excitation pulse was simulated for a range of AMP pulse amplitudes above the adiabatic threshold. Figure 1 C shows the simulated spectral profile for a range of B1 overdrive factors (i.e. percentage by which B1 was increased above the adiabatic threshold for the AMP pulse). Phantom Experiments: Phantom experiments were conducted using a 7T scanner (Echospeed whole-body magnet; GE Healthcare, Waukesha, WI, USA) to validate the pulse performance. The AMP pulse was added to a standard GRE sequence prior to the 90° excitation pulse in order to test if B1-insensitive T2-contrast was achieved. Images were obtained of a spherical agar phantom with the AMP sequence and a conventional spin echo (SE) sequence. TE was set to 63 ms for both sequences. The receive B1 profile was measured using a double angle method [8,9] and images were compensated by the measured profile to remove receive shading. In Vivo Experiments: Images of the brain of a normal volunteer were obtained at 7T using the AMP sequence and compared to a SE sequence as described for the phantom experiments. Acquisition parameters for both phantom and in vivo scans were: TE/TR= 63/1500 ms, matrix size=256x128, 5mm slice and FOV of 22x22cm. Results: See Fig. 2 for phantom images obtained using the (A) AMP pulse sequence, and (B) SE sequence. Central vertical cross sections through the images are shown in (C). The transmit B1 profile is significantly more uniform for the AMP pulse than the SE sequence, resulting in more uniform signal intensity. The 180° SLR pulse used in the SE sequence is overdriven at the center of the phantom, resulting in greater signal loss when compared to the AMP pulse. Figure 3 shows in vivo images obtained using the (A) AMP pulse sequence and (B) SE sequence. The AMP pulse achieves more uniform T2-contrast and SNR over the entire slice. Some B1-sensitivity still exists due to the linear phase excitation pulse. Discussion: In this work, we present a method to achieve B1insensitive T2-contrast at 7T utilizing an adiabatic magnetization preparation pulse. The contrast achieved is a combination of T2 and T2ρ contrast as the magnetization is spin-locked for the duration of the adiabatic pulse segments. In addition to greater immunity to the inhomogeneous RF field, the pulse is suitable for use as a T2 magnetization preparation pulse in a Fast Spoiled Gradient Recalled (FSPGR) sequence. Such a volumetric T2-weighted sequence is potentially advantageous at 7T because the AMP pulse need not be applied every TR, reducing the SAR and enabling greater spatial coverage at high resolution before exceeding SAR constraints. Our next step is to integrate the AMP pulse into an FSPGR sequence. References: [1] Atlas S, MRI of the Brain and Spine, Lippincott Williams & Wilkins, 1996. [2] Pauly J, et al. IEEE TMI 1991; 10(1):53–65. [3] Staewen RS, et al. Invest Radiol 1990; 25:559–567. [4] Garwood M, Ke Y. J Magn Reson 1991; 94:511–525. [5] De Graaf R, et al. JMR, Series B 1995;109(2):184–193. [6] Nezafat R, et al. MRM 2009; 61(6):1326 – 1335. [7] Balchandani P, et al. In Proceedings of ISMRM 17. Honolulu, 2009; 178. [8] Stollberger R, Wach P. MRM 1996;35(2):246–251. [9] Insko EK, Bolinger L. JMR, Series A 1993;103:82–85. Acknowledgements: Lucas Foundation, NIH R01 MH080913 and GE Healthcare. We thank Drs. John Pauly and Gary Glover for advice on pulse and sequence design. Figure 1: (A) Amplitude and (B) phase of AMP pulse. (C) The spectral profile of AMP pulse followed by a 90° excitation pulse plotted for the AMP pulse scaled to a range of B1 overdrive factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Contrast and Image Homogeneity with BIR4 Pulses in Magnetization Prepared Flair at 7 Tesla

Purpose: To improve image homogeneity and contrast of 3D FLAIR images at 7T. Introduction: FLAIR images with good T2 weighting can be obtained at 7T if magnetization preparation (MP) is applied prior to inversion [1]. However, the SNR and contrast are still limited in areas where the transmit field amplitude (B1) is reduced or inhomogeneous, such as the temporal operculum, the temporal lobes an...

متن کامل

B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T.

At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for cor...

متن کامل

Adiabatic T2-preparation modules optimized for robustness toward cardiac motion and flow - a comparison with existing techniques at 3 Tesla

Background T2-imaging of the heart at 3 Tesla demands T2-preparations not only insensitive to B0 and B1, but also toward cardiac motion and flow in order to avoid flow artifacts and concomitant myocardial contamination and to preserve endocardial border definition. While more refocusing pulses per T2-prep duration improve robustness, they also increase SAR. We chose four BIREF-1 refocusing puls...

متن کامل

High-Field MR Venography using Adiabatic T2 Magnetization Preparation

Introduction Highlighting the lumen of veins while attenuating arterial signal in MRI can be of use for several clinical purposes such as guiding the placement of pacemaker leads [1] or the diagnosis of venous thrombi [2]. At a magnetic field strength of 1.5 T, coronary venography has successfully been implemented with magnetization transfer contrast (MTC) [3] prepulses. Unfortunately this appr...

متن کامل

Spectrally Selective B1 Insensitive T2 Preparation Sequence for 3T Imaging

R. Nezafat, J. A. Derbyshire, R. Ouwerkerk, M. Stuber, E. R. McVeigh Lab of Cardiac Energetics, Division of Intramural Research, NHLBI, NIH, DHHS, Bethesda, MD, United States, Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States, Radiology, Johns Hopkins University, Baltimore, MD, United States Introduction: T2 magnetization preparation (T2 Prep) and spectrally selecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009