In Vitro Evaluation of the Effect of Core Thickness and Fabrication Stages on the Marginal Accuracy of an All-Ceramic System

نویسندگان

  • F. Farid
  • H. Hajimiragha
  • R. Jelodar
  • A. S. Mostafavi
  • H. Nokhbatolfoghahaie
چکیده

OBJECTIVE To evaluate the influence of core thickness and fabrication stages on the marginal accuracy of IPS e.max Press crowns. MATERIALS AND METHODS Twenty IPS e.max Press crowns, 1.5mm thick, were fabricated on metal dies. The crowns had two different core thicknesses, 0.8mm for group A and 1mm for group B, ten for each group. Marginal gap was measured after each stage of core fabrication, veneering and glaze firing. The specimens were not cemented and the measurements were made at four points on metal dies using a stereomicroscope (×120). Data were analyzed by SPSS software and independent t-test. RESULTS Mean marginal gaps measured after each stage for group A were 13.5 (±1.4) μm, 33.9 (±2.3) μm and 40.5(±1.7) μm, and for group B these figures were 14.9(±2.0) μm, 35.5(±2.2) μm and 41.3(±2.0) μm. There were no statistically significant differences in marginal gap values between the two groups (p>0.1). Significant increase in gap was observed after the veneering stage in both groups (p<0.05). After glazing, no significant increase in gap was detected. CONCLUSION IPS e.max Press crowns have an acceptable marginal fit. Increasing thickness of core does not increase marginal fitness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Core Thickness and Porcelain Sintering on Marginal Adaptation

Background and aim: Marginal adaptation affects the long-term success of full-coverage restorations. This study aimed to assess the effect of porcelain sintering and zirconia core thickness on the marginal adaptation of all-ceramic restorations. Materials and methods: In this in-vitro experimental study, a standard brass die, 7 mm in length and 5 mm in diameter, was fabricated using a milling ...

متن کامل

The Effect of Different Finishing Lines on the Marginal Fitness of Full Contour Zirconia and Glass Ceramic CAD/CAM Crowns (An in-vitro study)

Purpose: The aim of this study was to evaluate the effect of two gingival finishing lines (90° shoulder and deep chamfer) on the marginal fitness of two types of full anatomic all-ceramic crowns; zirconia crowns (Zikonzhan) and glass ceramic crowns (IPS e-max CAD) milled with CAD/CAM system. Materials and Methods: Two dentoform teeth of left maxillary first molar were prepared with chamfer fini...

متن کامل

اثر کلار در تغییر شکل مارژین روکش های ساخته شده از آلیاژ بیس متال

It has been shown that noble alloys require metal collar to resist distortion when subjected to repeat firing cycle of porcelain. Metal collar is undesirable due to esthetic concerns. Since base metal alloys have superior physical properties, it seems that metal collar would not be necessary for obtaining better marginal adaptation of base metal crowns. The Purpose of this study was to evaluate...

متن کامل

بررسی تأثیر پخت مکرر بر رنگ سرامیک های دندانی و رنگ پذیری آنها در مواجهه با محلولهای رنگ زا

Introduction & Objective: Color matching between restoration and natural teeth is a common clinical problem. Despite careful shade selection, color of the restoration may be affected by fabrication procedures such as number of firing. Moreover, color stability is an important factor to ensure the long-term clinical success of ceramic restorations. There is a lack of information about color c...

متن کامل

Effect of marginal design on fracture resistance of IPS e.maxall ceramic restorations: Chamfer versus shoulder finish lines

Background and Aim: One of the problems of all ceramic restorations is their risk of fracture due to occlusal loads. The aim of the present study was to compare the effect of two marginal designs (shoulder and chamfer) on the fracture resistance of IPS-emax all ceramic restorations. Materials and Methods: One extracted maxillary first premolar received chamfer 50' marginal preparation (0.8 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2012