Power system insulator condition monitoring automation using mean shift tracker-FIS combined approach
نویسندگان
چکیده
Within the hierarchy of power system, distribution system automation plays a crucial role to provide reliable service to customers. Though initially computer aided automation started as substation monitoring system (SMS) just for monitoring some key parameters such as voltage and currents of different components in a substation, the technological advancement has enabled to have access to more features from components of the entire distribution system. Since the distribution system has expanded to cater power to even remote locations, thus for reliable power supply, insulator condition monitoring automation plays an important role because the failure of insulator either causes complete disruption of power or reduction of system voltage leading to heavy power losses. This paper presents a methodology for condition monitoring automation of insulators by a combined approach using mean shift tracker and fuzzy inference system (FIS) and the case studies validate the efficacy of the methodology.
منابع مشابه
Maximum Power Point Tracker for Photovoltaic Systems Based on Moth-Flame Optimization Considering Partial Shading Conditions
The performance of photovoltaic (PV) systems is highly dependent on environmental conditions. Due to probable changes in environmental conditions, the real-time control of PV systems is essential for exploiting their maximum possible power. This paper proposes a new method to track the maximum power point of PV systems using the moth-flame optimization algorithm. In this method, the PV DC-DC co...
متن کاملReview of Machine Vision Based Insulator Inspection Systems for Overhead Power Distribution System
Received Sep 13, 2017 Revised Nov 13, 2017 Accepted Nov 21, 2017 The necessity to have reliable and quality power distribution is increasing, and hence there is great scope for research on automation of distribution system. There are signs of increased research in the work on condition monitoring of insulators during the last few decades. The possible failures can be predicted before they actua...
متن کاملA Fast Voltage Collapse Detection and Prevention Based on Wide Area Monitoring and Control
Voltage stability is one of the most important factors in maintaining reliable operation of power systems. When a disturbance occurs in the power system, it usually causes instabilities and sometimes leads to voltage collapse (VC). To avoid such problems, a novel approach called Vector Analysis (VA) is proposed that exploits a new instability detection index to provide wide area voltage stabili...
متن کاملCondition Monitoring Techniques of Power Transformers: A Review
Power transformers provide a vital link between the generation and distribution of produced energy. Such static equipment is subjected to abuse during operation in generation and distribution stations and leads to catastrophic failures. This paper reviewed the techniques in the field of condition monitoring of power transformers in recent years. Transformer monitoring and diagnosis are the effe...
متن کاملEagle Strategy Based Maximum Power Point Tracker for Fuel Cell System
A bunch of factors including the limited fossil resources and rising of fossil fuel price have been causes moving to create the new structure that is based on providing energy security, and protect the environment. One of the alternatives is the fuel cell (FC). Maximum power point tracker has an important role to increase the efficiency of the FC systems. One of the difficulties in maximum powe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IJCAET
دوره 5 شماره
صفحات -
تاریخ انتشار 2013