Pacing the human cardiac conduction system during open-heart surgery.

نویسندگان

  • J Kupersmith
  • E Krongrad
  • F O Bowman
  • J R Malm
  • A L Waldo
چکیده

Specialized fiber electrograms were recorded from selected sites along the His bundle and bundle branches during open-heart surgery in 26 patients. The heart was then paced from the same recording sites. Stimuli applied to the proximal His bundle recording site always resulted in His bundle pacing, which was characterized by a stimulus artifact-to-QRS interval which equaled or very nearly equaled the previously recorded His bundle electrogram-to-QRS interval, and no change in QRS duration or waveform from that recorded with a conducted atrial beat. Wher stimuli were applied to distal His bundle recording sites, the response was variable: in some instances, ventricular pacing occurred; in other instances, His bundle pacing occurred; and in still other instances, ventricular pacing occurred when high stimulus amplitudes were applied, while His bundle pacing occurred when the stimulus amplitudes were reduced below a range of 0.5-3.5 ma. Stimuli applied to the right or left bundle branch recording sites always resulted in ventricular pacing. Therefore, when stimuli are applied to specialized fiber recording sites and His bundle pacing results, it is certain that the site of origin of the previously recorded specialized fiber electrogram is the His bundle, but when ventricular pacing results, the site of origin of the previously recorded specialized fiber electrogram could be the distal His bundle or the bundle branches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atrial excitability and conduction during rapid atrial pacing.

Using temporary atrial wire electrodes placed at selected atrial sites, rapid atrial pacing at rates of up to 368 beats/min was used to study atrial excitability and conduction in seven patients who underwent open heart surgery. The threshold for atrial pacing was found to be an exponential function of pacing rate (r = 0.55, p less than 0.01), increasing threefold when the fastest pacing rates ...

متن کامل

Pacing the Human Cardiac Conduction System

Specialized fiber electrograms were recorded from selected sites along the His bundle and bundle branches during open-heart surgery in 26 patients. The heart was then paced from the same recording sites. Stimuli applied to the proximal His bundle recording site always resulted in His bundle pacing, which was characterized by a stimulus artifact-to-QRS interval which equaled or very nearly equal...

متن کامل

Ivabradine Versus Beta-Blockers in Patients with Conduction Abnormalities or Left Ventricular Dysfunction Undergoing Cardiac Surgery

INTRODUCTION In patients with conduction abnormalities or left ventricle (LV) dysfunction the use of β-blockers for post cardiac surgery rhythm control is difficult and controversial, with a paucity of information about other drugs such ivabradine used postoperatively. The objective of this study was to compare the efficacy and safety of ivabradine versus metoprolol used perioperatively in card...

متن کامل

Biventricular pacing in a patient with ventilatory and inotropic dependant heart failure following coronary artery by-pass surgery.

Resynchronisation of intra- and interventricular conduction delay by biventricular pacing has become a proven therapy for selected heart failure patients. We present a case of biventricular pacing, used with great success, as a 'bail out' for a patient with refractory congestive heart failure following by-pass surgery.

متن کامل

Right atrial free wall conduction velocity and degree of anisotropy in patients with stable sinus rhythm studied during open heart surgery.

AIMS Although the perpetuation of several supraventricular arrhythmias is critically dependent upon intra-atrial conduction, the literature lacks detailed information on normal values of conduction velocity and degree of anisotropy. In order to explore these factors further, we have measured conduction velocities at the right atrial free wall during sinus rhythm and during atrial pacing in four...

متن کامل