چکیده

For human-centered automation, this study presents a wireless sensor network using predicted mean vote (PMV) as a thermal comfort index around occupants in buildings. The network automatically controls air conditioning by means of changing temperature settings in air conditioners. Interior devices of air con-ditioners thus do not have to be replaced. An adaptive neurofuzzy inference system and a particle swarm algorithm are adopted for solving a nonlinear multivariable inverse PMV model so as to de-termine thermal comfort temperatures. In solving inverse PMV models, the particle swarm algorithm is more accurate than ANFIS according to computational results. Based on the comfort temper-ature, this study utilizes feedforward– feedback control and digital self-tuning control, respectively, to satisfy thermal comfort. The control methods are validated by experimental results. Compared with conventional fi xed temperature settings, the present control methods effectively maintain the PMV value within the range of and energy is saved more than 30% in this study. Note to Practitioners—For advanced control of unitary air conditioners in rooms, air conditioners may have to be retrofitted or con-nected with extra devices by wire connection, whose processes may be difficult for users, and inappropriate installation may damage original air-conditioning units. This study hence presents a nonin-vasive method for indoor thermal comfort with a wireless sensor network. The present method facilitates hardware implementation without changing interior devices of the air conditioner. The wire-less sensor network measures temperature, air velocity, and hu-midity around occupants and further transmits temperature com-mands for air conditioner control. Based on the measured data, a PMV model is adopted to evaluate thermal comfort. Using an inverse PMV model with feedforward– feedback control and self-tuning control, respectively, this study aims to automatically main-tain human thermal comfort as well as save energy. The ANFIS model and a particle swarm algorithm are used to solve the in-verse PMV model and determine the thermal comfort tempera-ture. Based on that temperature, feedforward–feedback control, and self-tuning control are used to determine appropriate temper-ature settings in the air conditioner so as to change the cooling ca-pacity and maintain thermal comfort. Experimental results show that the present control method can maintain thermal comfort and saves 30% more energy than the conventional method. Index Terms – Adaptive neurofuzzy inference system, automatic air conditioning control, particle swarm algorithm, predicted mean vote (PMV), self-tuning control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems

The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...

متن کامل

Thermal Comfort Feelings Assessment Based on Digital Signal Processor

In this paper, a new technique is being proposed to estimate the PMV by using an array of sensors for the automatic control of thermal sensation scale of the air conditioning system. The predicted mean vote (PMV) is a well recognized thermal comfort index and is used for measuring comfort level inside the conditioned space. It is a mathematical function dependent on air temperature, relative hu...

متن کامل

A Hybrid Intelligent Control System Based on PMV Optimization for Thermal Comfort in Smart Buildings

With the fast development of human society, on one hand, environmental issues have drawn incomparable attention, so energy efficiency plays a significant role in smart buildings; on the other hand, spending more and more time in buildings leads occupants constantly to improve the quality of life there. Hence, how to manage devices in buildings with the aid of advanced technologies to save energ...

متن کامل

Effect of opening diffuser and return vent location on air quality, thermal comfort and energy saving in desk displacement ventilation (DDV) system

Many investigations have recently been performed on return vent height and indicate that having 1.3 m distance from the floor is the optimized height for it. In this article, the effect of distance between opening diffuser and return vent on air quality, thermal comfort and energy saving was investigated. According to the results, by increasing the distance between opening and return vent up to...

متن کامل

Estimation of Thermal Comfort by Measuring Clo Value without Contact

In order to create more comfortable and energy saving living spaces, we have to investigate what is comfortable and how to measure comfort of users in a living space. Some measures of thermal comfort have been defined as Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD) as an international standard. However, complex and high cost equipments are required to measure PMV by con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016