Comparison of the FLUKA calculations with CAPRICE94 data on muons in atmosphere

نویسندگان

  • G. Battistoni
  • A. Ferrari
  • T. Montaruli
  • P. R. Sala
چکیده

In order to benchmark the 3-dimensional calculation of the atmospheric neutrino flux based on the FLUKA Monte Carlo code, muon fluxes in the atmosphere have been computed and compared with data taken by the CAPRICE94 experiment at ground level and at different altitudes in the atmosphere. For this purpose only two additions have been introduced with respect to the neutrino flux calculation: the specific solar modulation corresponding to the period of data taking and the bending of charged particles in the atmosphere. Results are in good agreement with experimental data, although improvements in the model are possible. At this level, however, it is not possible to disentangle the interplay between the primary flux and the interaction model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo Calculation of Muon Flux at Ground Level from Primary Cosmic Gamma Rays

The Monte Carlo program FLUKA was used to calculate the number of muons reaching detection level in events initiated by primary cosmic gamma ray interactions in the atmosphere. The calculation was motivated by the desire to gauge the sensitivity of arrays like that of Project GRAND to primary gamma cosmic rays while measuring single muons at detection level. Because direct gamma pair production...

متن کامل

Predicting Neutron Production from Cosmic-ray Muons

Fast neutrons from cosmic-ray muons are an important background to underground low energy experiments. The estimate of such background is often hampered by the difficulty of measuring and calculating neutron production with sufficient accuracy. Indeed substantial disagreement exists between the different analytical calculations performed so far, while data reported by different experiments is n...

متن کامل

Application of FLUKA code to gamma-ray attenuation, energy deposition and dose calculations

Background: In radiation therapy, water is the phantom material of choice, both for reference and for relative dosimetry measurements. Solid phantoms, however, are more useful for routine measurements because they tend to be more robust and easier to set up than water phantoms. Materials and Methods: FLUKA input data cards have been arranged in sequential order. A simple cylindrical geometry wi...

متن کامل

Theoretical Assessment of Aircrew Exposure to Galactic Cosmic Radiation Using the FLUKA Monte Carlo Code

Following the publication of the ICRP 1990 recommendations, the need to assess the dose received by aircrew and frequent flyers during air travel has arisen. The ICRP stated that exposure of aircrew to cosmic radiation should be considered as occupational exposure. Several countries have already implemented the ICRP recommendations. Due to the wide range of particles and energies at aircraft fl...

متن کامل

The FLUKA code: present applications and future developments

The main features of the FLUKA Monte Carlo code, which can deal with transport and interaction of electromagnetic and hadronic particles, are summarised. The physical models embedded in FLUKA are mentioned, as well as examples of benchmarking against experimental data. A short history of the code is provided and the following examples of applications are discussed in detail: prediction of calor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001