A simple breathing circuit minimizing changes in alveolar ventilation during hyperpnoea.

نویسندگان

  • L Z Sommer
  • S Iscoe
  • A Robicsek
  • J Kruger
  • J Silverman
  • J Rucker
  • J Dickstein
  • G A Volgyesi
  • J A Fisher
چکیده

Many clinical and research situations require maintenance of isocapnia, which occurs when alveolar ventilation (V'A) is matched to CO2 production. A simple, passive circuit that minimizes changes in V'A during hyperpnoea was devised. It is comprised of a manifold, with two gas inlets, attached to the intake port of a nonrebreathing circuit or ventilator. The first inlet receives a flow of fresh gas (CO2=0%) equal to the subject's minute ventilation (V'E). During hyperpnoea, the balance of V'E is drawn (inlet 2) from a reservoir containing gas, the carbon dioxide tension (PCO2) approximates that of mixed venous blood and therefore contributes minimally to V'A. Nine normal subjects breathed through the circuit for 4 min at 15-31 times resting levels. End-tidal PCO2 (Pet,CO2) at rest, 0, 1.5 and 3.0 min were (mean+/-SE) 5.1+/-0.1 kPa (38.1+/-1.1 mmHg), 4.9+/-0.1 kPa (36.4+/-1.1 mmHg), 5.0+/-0.2 kPa (37.8+/-1.6 mmHg) and 5.0+/-0.2 kPa (37.6+/-1.4 mmHg) (p=0.53, analysis of variance (ANOVA)), respectively; without the circuit, Pet,CO2 would be expected to have decreased by at least 2.7 kPa (20 mmHg). Six anaesthetized, intubated dogs were first ventilated at control levels and then hyperventilated by stepwise increases in either respiratory frequency (fR) from 10 to 24 min(-1) or tidal volume (VT) from 400 to 1,200 mL. Increases in fR did not significantly affect arterial CO2 tension (Pa,CO2) (p=0.28, ANOVA). Only the highest VT decreased Pa,CO2 from control (-0.5 +/- 0.3 kPa (-3.4 +/- 2.3 mmHg), p<0.05). In conclusion, this circuit effectively minimizes changes in alveolar ventilation and therefore arterial carbon dioxide tension during hyperpnoea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compartmental chest wall volume changes during volitional hyperpnoea with constant tidal volume in healthy individuals.

Prolonged high-intensity ventilation is associated with the development of rapid shallow breathing with decreased end-inspiratory volumes of all chest wall compartments. During respiratory muscle endurance training using normocapnic hyperpnoea, tidal volume (V(T)) is normally kept constant. The aim of this study was to investigate possible changes in muscle recruitment during constant-V(T) hype...

متن کامل

Effect of acute hypoxia on respiratory muscle fatigue in healthy humans

BACKGROUND Greater diaphragm fatigue has been reported after hypoxic versus normoxic exercise, but whether this is due to increased ventilation and therefore work of breathing or reduced blood oxygenation per se remains unclear. Hence, we assessed the effect of different blood oxygenation level on isolated hyperpnoea-induced inspiratory and expiratory muscle fatigue. METHODS Twelve healthy ma...

متن کامل

Simple contrivance "clamps" end-tidal PCO(2) and PO(2) despite rapid changes in ventilation.

The device described in this study uses functionally variable dead space to keep effective alveolar ventilation constant. It is capable of maintaining end-tidal PCO(2) and PO(2) within +/-1 Torr of the set value in the face of increases in breathing above the baseline level. The set level of end-tidal PCO(2) or PO(2) can be independently varied by altering the concentration in fresh gas flow. T...

متن کامل

بررسی نقش کام‌نرم در تبدیل تنفس بینی به بینی‌دهانی در حین ورزش در افراد سالم غیر ورزشکار

Background and Objective: Breathing through the nose and mouth is one of the controversial issues during exercise. The present study was scheduled to investigate a quantitative approach to habitual versus the obligatory switching point from nasal to oronasal breathing during exercise as well as coincidence of soft palate movement as the main aims of this study, that has not been studied previou...

متن کامل

The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.

BACKGROUND Passive humidifiers have gained acceptance in the intensive care unit because of their low cost, simple operation, and elimination of condensate from the breathing circuit. However, the additional dead space of these devices may adversely affect respiratory function in certain patients. This study evaluates the effects of passive humidifier dead space on respiratory function. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 1998