X-Ray Imaging with a Silicon Microstrip Detector

نویسندگان

  • T. Mali
  • V. Cindro
  • M. Mikuz
  • U. Zdesar
چکیده

A single photon counting X-ray imaging system, with possible applications to dual energy mammography and angiography, is presented. A silicon microstrip detector with 100 mm pitch strips is coupled to RX64 ASICs, each of them including 64 channels of preamplifier, shaper, discriminator and scaler. The system has low noise, good spatial resolution and high counting rate capability. Results on energy resolution have been obtained with a fluorescence source and quasi-monochromatic X-rays beams. Preliminary images obtained with an angiographic phantom are

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antihydrogen annihilation reconstruction with the ALPHA silicon detector

The ALPHA experiment has succeeded in trapping antihydrogen, a major milestone on the road to spectroscopic comparisons of antihydrogen with hydrogen. An annihilation vertex detector, which determines the time and position of antiproton annihilations, has been central to this achievement. This detector, an array of double-sided silicon microstrip detector modules arranged in three concentric cy...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Development of MicroStrip Gaseous Chamber for Realtime X-ray Imaging Detector

The MicroStrip Gaseous Chamber (MSGC) was proposed in 1988 [1] as a new type of proportional gaseous detector providing an excellent position resolution. A very fine pitch (<200μm) of signal lines, which could be realized by printing several hundred of strips on a substrate using the Multi-Chip Module technology [2, 3],makes possible to satisfy almost all requirements for X-ray position detecto...

متن کامل

Performance of a Ge-microstrip imaging detector and polarimeter.

Using 98% linearly polarized radiation at the European Synchrotron Radiation Facility in Grenoble, the performance of a prototype two-dimensional microstrip Ge(i) detector for x-ray imaging and as a Compton polarimeter has been evaluated. Using the energy and position sensitivity of the detector, the ability to obtain a complete reconstruction of the Compton event has been demonstrated. The mod...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998