Disseminated mycobacteriosis affecting a prosthetic aortic valve: first case of Mycobacterium peregrinum type III reported in Colombia.

نویسندگان

  • Carlos A Torres-Duque
  • Claudia Díaz
  • Leslie Vargas
  • Elsa María Serpa
  • Walter Mosquera
  • María Consuelo Garzón
  • Graciela Mejía
  • Luz Mary García
  • Liliana Andrea González
  • Claudia Marcela Castro
  • Wellman Ribón
چکیده

Rapidly growing mycobacteria are non-tuberculous mycobacteria amply present in the environment. Although they are not usually pathogenic for humans, they are opportunistic in that they can cause disease in people with disadvantageous conditions or who are immunocompromised. Mycobacterium peregrinum, an opportunistic, rapidly growing mycobacteria, belongs to the M. fortuitum group and has been reported as responsible for human cases of mycobacteriosis. A case of M. peregrinum type III is herein reported as the first in Colombia. It presented as a disseminated disease involving a prosthetic aortic valve (endocarditis) in a seventeen-year-old girl with a well-established diagnosis of prosthetic aortic valve endocarditis who was referred for a surgical replacement. Due to a congenital heart disease (subaortic stenosis with valve insufficiency), she had two previous aortic valve implantation surgeries. One year after the second implantation, the patient presented with respiratory symptoms and weight lost indicative of lung tuberculosis. A chest X-ray did not show parenchymal compromise but several Ziehl-Neelsen stains were positive. An echocardiography showed a vegetation on the prosthetic aortic valve. In blood and sputum samples, M. peregrinum type III was identified through culture, biochemical tests and hsp65 gene molecular analysis (PRA). The patient underwent a valve replacement and received a multidrug antimycobacterial treatment. Progressive recovery ensued and further samples from respiratory tract and blood were negative for mycobacteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Occurrence and antimicrobial susceptibility of Mycobacterium peregrinum in ornamental fish

Systemic mycobacteriosis was diagnosed in a group of ornamental fish. Although a large number of acid-fast bacterial rods were identified in the kidneys, liver, and muscles of each fish, no granulomas were observed in internal organs. Mycobacterium peregrinum was identified using the GenoType Mycobacterium CM assay. This study illustrates a considerable risk of atypical mycobacteriosis in humans.

متن کامل

Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review

Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedica : revista del Instituto Nacional de Salud

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 2010