Revisiting sweat chloride test results based on recent guidelines for diagnosis of cystic fibrosis

نویسندگان

  • Jayson V. Pagaduan
  • Mahesheema Ali
  • Michael Dowlin
  • Liye Suo
  • Tabitha Ward
  • Fadel Ruiz
  • Sridevi Devaraj
چکیده

Objectives Recent sweat chloride guidelines published by the Cystic Fibrosis Foundation changed the intermediate sweat chloride concentration range from 40-59 mmol/L to 30-59 mmol/L for age > 6 months. We wanted to know how this new guideline would impact detection of cystic fibrosis among patients who previously had sweat tests done at Texas Children's Hospital. Methods We revisited sweat chloride test results (n = 3012) in the last 5 years at Texas Children's Hospital based on the new guidelines on diagnosis of cystic fibrosis from the Cystic Fibrosis Foundation. Results We identified 125 patients that would be reclassified in the intermediate sweat chloride value with the new guidelines that were classified as "unlikely to have CF" in the previous guidelines. 8 (32%) patients with CFTR gene testing were positive for CFTR gene mutation(s). 4 (50%) of these patients were identified to have 2 CFTR mutations. One had variant combination that was reported to cause CF but all were diagnosed with CFTR-related metabolic syndrome. Conclusion Our findings concur with the new CF diagnosis guidelines that changing the intermediate cut-off to 30-59 mmol/L sweat chloride concentration in combination with CFTR genetic analysis enhances the probability of identifying individuals that have risk of developing CF or have CF and enables for earlier therapeutic intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence of Cystic Fibrosis Trans-membrane Conductance Regulator Gene common mutations in children with cystic fibrosis in Isfahan, Iran

Background: Cystic fibrosis (CF) is the most common lethal genetic disorder of Cystic Fibrosis Trans-membrane Conductance (CFTR) Regulator gene mutations. We aimed to investigate common mutations in CF patients and to assess its possible relationship with clinical presentations. Materials and Methods: This cross sectional study was conducted on 36 CF patients who were referred to a tertiary ped...

متن کامل

Stratifying Cystic Fibrosis Risk for Newborn Screen Infants With Equivocal Sweat Chloride Levels.

Risk for Newborn Screen Infants With Equivocal Sweat Chloride Levels We read with interest the recent study by Ooi et al, which adds significantly to the recent literature guiding physicians on how to manage infants with equivocal sweat chloride (30–59 mmol/L, termed cystic fibrosis [CF] screen positive, inconclusive diagnosis [CFSPID]) identified through newborn screening. Nine (11%) of 82 sub...

متن کامل

Evidence based guidelines for the performance of the sweat test for the investigation of cystic fibrosis in the UK.

A well produced evidence based guideline has been developed in response to a national audit that demonstrated wide variations in the performance of sweat tests. Accurate and reliable sweat test results will be particularly important with the advent of neonatal screening. The guideline recommendations include the collection and analysis of sweat samples, and interpretation of results. It emphasi...

متن کامل

Comparison of Classic Sweat Test and Crystallization Test in Diagnosis of Cystic Fibrosis

OBJECTIVE Sweat chloride measurement is considered a standard diagnostic tool for cystic fibrosis (CF). This study was performed to compare sweat chloride values obtained by quantitative pilocarpine iontophoresis (classic test) with sweat crystallization detected by direct observation of a drop of perspiration under light microscopy in patients with and without CF. METHODS The tests using bot...

متن کامل

Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia

INTRODUCTION Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018