Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation.

نویسندگان

  • Giorgio Della Rocca
  • Maria Gabriella Costa
  • Cecilia Coccia
  • Livia Pompei
  • Pierangelo Di Marco
  • Vincenzo Vilardi
  • Paolo Pietropaoli
چکیده

PURPOSE The PiCCO System is a relatively new device allowing intermittent cardiac output monitoring by aortic transpulmonary thermodilution technique (Aorta intermittent) and continuous cardiac output monitoring by pulse contour analysis (Aorta continuous). The objective of this study was to assess the level of agreement of Aorta intermittent and Aorta continuous with intermittent (PA intermittent) and continuous cardiac output (PA continuous) measured through a special pulmonary artery catheter (Vigilance System SvO(2)/CCO Monitor) in patients undergoing single- or double-lung transplantation. METHODS Measurements were obtained in 58 patients: at four time points in patients undergoing single-lung transplantation and at six time points in those undergoing double-lung transplantation. Bland and Altman and correlation analyses were used for statistical evaluation. RESULTS We found close agreement between the techniques. Mean bias between Aorta intermittent and PA intermittent and between Aorta continuous and PA continuous was 0.18 L x min(-1) (2SD of differences between methods = 1.59 L x min(-1)) and -0.07 L x min(-1) (2SD of differences between methods = 1.46 L x min(-1)) respectively. Mean bias between PA continuous and PA intermittent and Aorta continuous and PA intermittent was 0.15 L x min(-1) (2SD of differences between methods = 1.39 L x min(-1)) and 0.08 L x min(-1) (2SD of differences between methods = 1.43 L x min(-1)). CONCLUSION Measurements with the aortic transpulmonary thermodilution technique give continuous and intermittent values that agree with the pulmonary thermodilution method which is still the current clinical standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique.

BACKGROUND Cardiac output (CO) can be measured intermittently by bolus thermodilution methods in the pulmonary artery (COpa) or in the aorta (COart). A continuous thermodilution method (CCO) and a method for continuous estimation using the arterial pulse wave (PCCO) are also available. METHODS We compared two methods of intermittent CO measurements in patients during liver transplantation: CO...

متن کامل

Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis.

BACKGROUND Recently, continuous monitoring of cardiac output (CO) based on pulse contour analysis (Vigileo) has been introduced into practice. In this clinical study, we evaluated the accuracy of this system by comparing it with the transpulmonary thermodilution technique (TPID) in septic patients. METHODS We studied 24 mechanically ventilated patients with septic shock (16 male, 8 female, ag...

متن کامل

A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery

Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary b...

متن کامل

Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.

BACKGROUND Cardiac output monitoring, as a part of a goal-directed haemodynamic management, has been shown to improve perioperative outcome in high-risk patients undergoing major surgical interventions. However, thorough validation of cardiac output monitoring devices in different clinical conditions is warranted. The aim of our study was to compare the reliability of a novel system for cardiac...

متن کامل

Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO). The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 50 7  شماره 

صفحات  -

تاریخ انتشار 2003