Estimation of the end of ejection in aortic stenosis: an unreported source of error in the invasive assessment of severity.
نویسندگان
چکیده
BACKGROUND All indices of aortic stenosis (AS) rely on measurements of mean transvalvular pressure gradient (DeltaP) and flow rate. Because the gradient is reversed during late ejection, the late systolic left ventricular (LV)-aortic pressure crossover may be an erroneous landmark of end-ejection. The aortic incisura should be a better reference to calculate indices of AS invasively. METHODS AND RESULTS The accuracy of the pressure crossover and the incisura to define end-ejection was assessed in a chronic AS experimental model (9 dogs) with the use of an implantable flowmeter and Doppler echocardiography as reference. In 288 hemodynamic recordings analyzed (aortic valve area [AVA]: 0.74+/-0.46 cm2), ejection ended 37+/-29 ms after the pressure crossover but almost simultaneously with the incisura (2+/-17 ms). Pressure crossover error accounted for significant errors in the measurement of DeltaP (95% limits of agreement, +0 to +7 mm Hg) and AVA (-0.1 to +0.2 cm2). These errors were reduced to less than half with the use of the incisura to define end-ejection. Additionally, the agreement with Doppler-derived AS indices was best with use of the incisura. Pressure crossover error was maximal in situations of higher output, moderate orifice narrowing, higher arterial compliance, and lower vascular resistance. In 32 consecutive patients undergoing cardiac catheterization for AS, the pressure crossover induced a clinically important overestimation of the DeltaP from +22 to +50%. Errors in AVA estimation were considerably smaller (-2% to +6%) because of simultaneous and offsetting errors in the measurements of DeltaP and flow. CONCLUSIONS The aortic incisura and not the second pressure crossover should be used to obtain invasive indices of AS.
منابع مشابه
Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملLate lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm
We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.
متن کاملبررسی یافتههای اکوکاردیوگرافی در بیماران مبتلا به حوادث عروق مغزی حاد
Background and Objective: Cerebrovascular accidents are one of the most common causes of disability and mortality in human population all over the world. Several factors such as age, sex, hypertension, hyperlipidemia and heart diseases are risk factors for stroke. ِDue to high prevalence of cerebrovascular accidents and its related risk factors and particularly heart diseases, we decided to stud...
متن کاملThe left ventricle in aortic stenosis – imaging assessment and clinical implications
Aortic stenosis has an increasing prevalence in the context of aging population. In these patients non-invasive imaging allows not only the grading of valve stenosis severity, but also the assessment of left ventricular function. These two goals play a key role in clinical decision-making. Although left ventricular ejection fraction is currently the only left ventricular function parameter that...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 110 9 شماره
صفحات -
تاریخ انتشار 2004