Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.

نویسندگان

  • A Kastrati
  • J Mehilli
  • J Dirschinger
  • F Dotzer
  • H Schühlen
  • F J Neumann
  • M Fleckenstein
  • C Pfafferott
  • M Seyfarth
  • A Schömig
چکیده

BACKGROUND Increased thrombogenicity and smooth muscle cell proliferative response induced by the metal struts compromise the advantages of coronary stenting. The objective of this randomized, multicenter study was to assess whether a reduced strut thickness of coronary stents is associated with improved follow-up angiographic and clinical results. METHODS AND RESULTS A total of 651 patients with coronary lesions situated in native vessels >2.8 mm in diameter were randomly assigned to receive 1 of 2 commercially available stents of comparable design but different thickness: 326 patients to the thin-strut stent (strut thickness of 50 microm) and 325 patients to the thick-strut stent (strut thickness of 140 microm). The primary end point was the angiographic restenosis (>/=50% diameter stenosis at follow-up angiography). Secondary end points were the incidence of reinterventions due to restenosis-induced ischemia and the combined rate of death and myocardial infarctions at 1 year. The incidence of angiographic restenosis was 15.0% in the thin-strut group and 25.8% in the thick-strut group (relative risk, 0.58; 95% CI, 0.39 to 0.87; P=0.003). Clinical restenosis was also significantly reduced, with a reintervention rate of 8.6% among thin-strut patients and 13.8% among thick-strut patients (relative risk, 0.62; 95% CI, 0.39 to 0.99; P=0.03). No difference was observed in the combined 1-year rate of death and myocardial infarction. CONCLUSIONS The use of a thinner-strut device is associated with a significant reduction of angiographic and clinical restenosis after coronary artery stenting. These findings may have relevant implications for the currently most widely used percutaneous coronary intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.

OBJECTIVES We tested the hypothesis that thinner-strut stents are associated with a reduced rate of restenosis when comparing two stents with different design. BACKGROUND We have previously shown that, for two stents with similar design, the risk for restenosis is dependent on the strut thickness. It is unknown whether strut thickness preserves its relevance as a determinant of restenosis eve...

متن کامل

Effect of glycoprotein IIb/IIIa receptor blockade with abciximab on clinical and angiographic restenosis rate after the placement of coronary stents following acute myocardial infarction.

OBJECTIVES In the Intracoronary Stenting and Antithrombotic Regimen-2 trial (ISAR-2), we sought to investigate the effect of abciximab on angiographic and clinical restenosis after stenting following acute myocardial infarction (AMI). We also intended to assess the impact of abciximab on clinical outcome in this setting. BACKGROUND It is unclear whether abciximab reduces neointima formation a...

متن کامل

The need for stent-lesion matching to optimize outcomes of intracoronary stent implantation.

Intracoronary stents have markedly improved the outcomes of catheter-based coronary interventions. Intracoronary stent implantation rates of over 90% during coronary angioplasty are common. Stent implantations are associated with a small but statistically significant number of adverse outcomes including restenosis, thrombosis, strut malapposition, incomplete strut endothelialization, and variou...

متن کامل

Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial.

BACKGROUND Intracoronary ultrasound (ICUS) has provided insights into vascular pathology and interventional therapy. The Strategy for ICUS-Guided PTCA and Stenting (SIPS) trial tested the hypothesis that routine ICUS guidance of coronary interventions improves outcome. METHODS AND RESULTS A single-center consecutive-patient randomized design (with 6-month angiographic and 2-year clinical foll...

متن کامل

Intracoronary ultrasound-guided stenting improves outcomes: a meta-analysis of randomized trials.

BACKGROUND Intracoronary ultrasound (IVUS) has been used as an adjunctive method in order to optimize implantation of stents. However, the impact of this method in some outcomes is controversial. OBJECTIVE To systematically review the impact of routine IVUS-guided coronary stent as compared to angiographic-guided, on clinical and angiographic outcomes. METHODS A search of databases (MEDLINE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vestnik rentgenologii i radiologii

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2001