Distribution of lung blood on modified bilateral Glenn shunt evaluated by Tc-99m-MAA lung perfusion scintigraphy

نویسندگان

  • Biao Si
  • Zhao-sheng Luan
  • Tong-jian Wang
  • Yan-song Ning
  • Na Li
  • Meng Zhu
  • Zhong-min Liu
  • Guang-hong Ding
  • Bin Qiao
چکیده

The aim of the present study was to determine the distribution of lung blood in a modified bilateral Glenn procedure designed in our institute with lung perfusion scintigraphy. Sixteen consecutive patients who underwent modified bilateral Glenn operation from 2011 to 2014 were enrolled in the study. The control group consisted of 7 patients who underwent bidirectional Glenn shunt. Radionuclide lung perfusion scintigraphy was performed using Tc-99m-macro aggregated albumin (MAA) in all patients. For the patients in modified bilateral Glenn group, the time at which the radioactivity accumulation peaked did not differ significantly between the right and left lung field (t = 0.608, P = 0.554). The incidence of perfusion abnormality in each lung lobe also did not differ significantly (P = 0.426 by Fisher exact test). The radioactive counts were higher in the right lung than in the left lung, but the difference was not statistically significant (t = 1.502, P = 0.157). Radioactive perfusion in the lower lung field was significantly greater than that in the upper field (t = 4.368, P < 0.001). Compared with that in the bidirectional Glenn group, the ratio of radioactivity in the right lung to that in left lung was significantly lower in the modified bilateral Glenn group (t = 3.686, P = 0.002). Lung perfusion scintigraphy confirmed the benefit of the modified bilateral Glenn shunt with regard to more balanced blood perfusion in both lungs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative lung perfusion scintigraphy and detection of intrapulmonary shunt in liver cirrhosis.

OBJECTIVE Frequent association between liver cirrhosis and hypoxemia has been well documented. It is mostly attributable to intrapulmonary shunt due to dilation of pulmonary vasculature. We performed quantitative lung perfusion scintigraphy to detect an intrapulmonary shunt in cirrhosis patients. METHODS Prior to injection, Tc-99m MAA was applied to thin layer chromatography for quality contr...

متن کامل

Combined Radionuclide Phlebography and V/Q scan in the assessment of iliac vein thrombosis and pulmonary embolism – A case report establishing a cause and effect relationship

Deep vein thrombosis (DVT) is an important life threatening condition that is difficult to diagnose, particularly in the early stages. Looking for DVT in lower limb can be considered ancillary in suspected cases of pulmonary embolism (PE) indirectly highlighting a cause and effect relationship of a single disease (i.e cause being DVT and effect is the assault on the lung vasculature). Prompt an...

متن کامل

Liver and vertebral visualization on lung perfusion scan.

A 45-yearold man with dyspnea was referred for lung perfusion scan. Extrapulmonary uptake of Tc-99m macroaggregated albumin (MAA) was noted in a small area of the liver and in the thoracic vertebrae (fig. 1); the findings were not seen in a repeated lung scan after administration of the tracer through a peripheral vein in the foot (fig. 2). Subsequent computed tomography of the thorax revealed ...

متن کامل

Reply to 'Accurate measurement of the normality values of macroaggregated albumin lung perfusion scan in hepatopulmonary syndrome'.

Dear Editor, It is with great interest that we reply to the letter of questions and comments of Dr. Prof. Xiao Li to the article ‘‘Evaluation of normality and reproducibility parameters of Tc-MAA scintigraphy in the diagnosis of intrapulmonary vascular dilatations’’. However, we do not agree with the criticism regarding the group evaluated and the protocol used for scintigraphy with technetium-...

متن کامل

Lower limb deep vein thrombosis in patients with suspected pulmonary embolism detected with (99m)Tc-MAA simultaneously with lung perfusion scan.

The aim of this study was to evaluate the incidence of deep vein thrombosis (DVT) in patients with suspected pulmonary embolism (PE) and the relation between PE and the site of DVT by using technetium-99m-macroaggregated human serum albumin ((99m)Tc-MAA) radionuclide venography (RNV). Technetium-99m-MAA RNV was performed simultaneously with lung perfusion scintigraphy in 123 patients with s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016