Role of 99mTc-MIBI scintimammography and X-ray mammography in the diagnosis of locoregional recurrence of breast cancer.

نویسندگان

  • Sharjeel Usmani
  • Khalid Niaz
  • Maseeh-Uz-Zaman
  • Shahid Kamal
  • Kashif Niyaz
  • Javed Mehboob
  • Adnan Hashmi
  • Salman Habib
  • Hina Hashmi
چکیده

OBJECTIVE To evaluate the utility of Tc- MIBI scintimammography in the loco-regional recurrence of breast cancer and its comparison with mammography. METHODS The study population comprised of 33 subjects (mean age, 44.9 +/- 14.1 years); evaluated for suspected loco-regional recurrence of breast cancer on clinical examination. All subjects received a 740-1000 MBq bolus IV injection of 99mTc-MIBI preferably in pedal vein. At 5-10 min and 60-90 min post injection planar images were obtained in prone lateral and supine anterior position using double head gamma camera. MIBI uptake was scored as follows: 1: as normal uptake (compared with contralateral side); 2: focal low intense uptake (equivocal); 3: focal high intense uptake (positive). Mammography was performed by two standard views of cranio-caudal and mediolateral oblique in 26 patients. All patients had either excision biopsy or fine needle aspiration cytology (FNAC) for tissue diagnosis. RESULTS Out of 33 patients, 21 had confirmed as recurrence on hiostopathology/cytology. Scintimammography was found true positive in 18 and true negative in 11 patients. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 85.7%, 91.7%, 94.7%, 78.6% and 87.8% respectively. In comparison, mammography was true positive in 9 and true negative in 6 patients with sensitivity of 52.9%, specificity, 66.7%, PPV 75%, NPV 42.9% and accuracy 57.7%. CONCLUSION Scintimammography has better diagnostic accuracy than mammography in the detection of loco-regional recurrence of breast cancer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارزش تشخیصی اسکن 99mTc-MIBI (Scintimammography) در بدخیمی های پستان

The breast cancer is common in females.Early detection with safe , convenient , noninvasive and accessible diagnostic tools are important. X- ray mammography is still the first choice imaging for breast cancer, but has low specificity and limited value in dense breast and surgically scarred breasts. In recent years , MIBI scintimammography has been used for this purpose. The...

متن کامل

The role of 99mTc-MIBI scientimammography in diagnosis of breast cancer

Scientimammography (SMM) is a new non-invasive method of imaging breast tumors which in various studies the overall sensitivity of 83%-95.8% and specificity of 52%-95% is reported. The purpose of our study was to evaluate the usefullness of 99mTc-MIBI SMM in our environment in detecting breast cancer and in reducing the rate of biopsy. 65 patients aged 23-70 years were included in this st...

متن کامل

Diagnostic value of 99mTc MIBI scintimammography in patients with breast lesions.

This study has aimed to determine the diagnostic value of the scintimammography with 99mTc-MIBI in the detection of primary breast cancer and to verify its clinical usefulness. Sixty-three female patients (age range 27-83) with breast lesions detected by physical examination, ultrasonography, and/or mammography were prospectively included in this study. An anterior and prone lateral planar 99mT...

متن کامل

Breast cancer imaging: a new role of Tc-99m sestamibi prone scintimammography for diagnosisof breast cancer

Mammography remians the procedure of choice in screening asymptomatic women for breast cancer. However, in patients with symptoms, other types of imaging play an important role in the detection of malignancies. The high cost and lack of availability of PET and MRI largely precludes the use in this patient population. TI-201 is nbt the imaging agent of choice because of its wash-out and redistri...

متن کامل

Detection of DCIS using 99mTc-MIBI scintimammography in patients with suspected primary breast cancer, comparison with conventional mammography.

BACKGROUND Scintimammography using Tc-99m MIBI (SMM) is often used clinically as a second line diagnostic test for the detection of breast cancer in cases where there is concern about the results of x-ray mammography (XMM) and ultrasound. Both of these methods, but particularly XMM, may miss a significant proportion of ductal carcinoma in situ (DCIS). MATERIAL AND METHODS This study was perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2007