Short-wavelength automated perimetry and standard perimetry in the detection of progressive optic disc cupping.

نویسندگان

  • C A Girkin
  • A Emdadi
  • P A Sample
  • E Z Blumenthal
  • A C Lee
  • L M Zangwill
  • R N Weinreb
چکیده

OBJECTIVE To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic disc detected by serial stereophotographs. METHODS Forty-seven glaucoma patients with at least 2 disc stereophotographs more than 2 years apart, along with standard perimetry and SWAP examinations within 6 months of each disc photo of the same eye, were included in the study. The mean follow-up time was 4.1 years (range, 2.0-8.9 years). Baseline and follow-up stereophotographs were then graded and compared for the presence of progression. Progression in standard perimetry and SWAP, using the Advanced Glaucoma Intervention Study scoring system and a clinical scoring system, was compared between eyes with progressive change on stereophotographs and those without. RESULTS Twenty-two of 47 eyes showed progressive change by stereophotographs. There was a statistically significant difference in the mean change in Advanced Glaucoma Intervention Study scores for both standard perimetry (P<.004) and SWAP (P<.001) between the progressed and nonprogressed groups. The sensitivity, specificity, and area under the receiver operator characteristic curve were higher using SWAP than standard perimetry when evaluated by either algorithm. This was statistically significant only in the area under the receiver operator characteristic curve for the Advanced Glaucoma Intervention Study scoring system (P =.04). CONCLUSIONS Short-wavelength automated perimetry identified more patients than standard perimetry as having progressive glaucomatous changes of the optic disc. Compared with standard perimetry, SWAP may improve the detection of progressive glaucoma. Arch Ophthalmol. 2000;118:1231-1236

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.

OBJECTIVE To compare the prevalence of structural and psychophysical abnormalities in normal eyes and eyes with glaucomatous optic neuropathy (GON) and normal standard automated perimetry (SAP). METHODS Complete examination, SAP, short-wavelength automated perimetry (SWAP), frequency doubling technology (FDT), scanning laser polarimetry (GDx-VCC), and optical coherence tomography (OCT) of the...

متن کامل

[Sensitivity of size I stimulus in achromatic automated perimetry for detection of glaucomatous visual field defects: a comparative analysis with short wavelength automated perimetry and standard automated perimetry (SITA)].

PURPOSE To compare sensitivity and specificity of achromatic perimetry with size I stimulus (WW-I) with standard automated perimetry (SITA strategy) and blue on yellow perimetry (SWAP) for early diagnosis of glaucoma. METHODS Seventy-three eyes of 73 suspects, glaucomatous and normal subjects underwent automated perimetry with SITA 24-2, WW-I and SWAP. After application of specific criteria o...

متن کامل

CLINICAL SCIENCES Detection of Psychophysical and Structural Injury in Eyes With Glaucomatous Optic Neuropathy and Normal Standard Automated Perimetry

Methods: Complete examination, SAP, shortwavelength automated perimetry (SWAP), frequency doubling technology (FDT), scanning laser polarimetry (GDx-VCC), and optical coherence tomography (OCT) of the peripapillary retinal nerve fiber layer (RNFL), optic disc, and macula were performed. Glaucomatous optic neuropathy was defined as cup-disc asymmetry between fellow eyes of greater than 0.2, rim ...

متن کامل

Long-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.

PURPOSE To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry. MET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 118 9  شماره 

صفحات  -

تاریخ انتشار 2000