In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System.
نویسندگان
چکیده
Use of autotransfusion systems to collect, wash, and concentrate shed blood during surgical procedures is a widely used method for reducing postoperative anemia and the need for blood transfusions. The aim of this study was to evaluate the CATSmart Continuous Autotransfusion System wash program performance with small (200 or 700 mL) and large volumes (1,000 mL) of shed blood and to determine non-inferiority of the CATSmart to the C.A.T.S plus system. Human whole blood was collected in citrate phosphate dextrose, diluted, and divided into two aliquots to be processed as a pair using the C.A.T.S plus and CATSmart systems with their corresponding wash programs: low-volume, high quality/smart, or emergency wash. Final packed red cell product was analyzed for red blood cell (RBC), white blood cell, and platelet counts; hemoglobin; hemolysis; RBC recovery rates; and elimination of albumin, total protein, and potassium. The mean hematocrit (HCT) after processing with CATSmart and C.A.T.S plus systems were 59.63% and 57.71%, respectively. The calculated overall RBC recovery rates on the CATSmart and C.A.T.S plus systems were 85.41% and 84.99%, respectively. Elimination of albumin (97.5%, 98.0%), total proteins (97.1%, 97.5%), and potassium (92.1%, 91.9%) were also calculated for the CATSmart and C.A.T.S plus systems. The CATSmart and C.A.T.S plus systems both provided a high-quality product in terms of HCT, protein elimination, and hemolysis rates across the range of tested shed blood volumes and all wash programs. The study was able to confirm the CATSmart is non-inferior to the C.A.T.S plus system.
منابع مشابه
The clinical value of parenteral immunonutrition in surgical patients
Record Status This is a critical abstract of an economic evaluation that meets the criteria for inclusion on NHS EED. Each abstract contains a brief summary of the methods, the results and conclusions followed by a detailed critical assessment on the reliability of the study and the conclusions drawn. Health technology The authors assessed parenteral nutrition (PN) in surgical patients. Three s...
متن کاملThe clinical value of parenteral immunonutrition in surgical patients
Record Status This is a critical abstract of an economic evaluation that meets the criteria for inclusion on NHS EED. Each abstract contains a brief summary of the methods, the results and conclusions followed by a detailed critical assessment on the reliability of the study and the conclusions drawn. Health technology The authors assessed parenteral nutrition (PN) in surgical patients. Three s...
متن کاملErratum to: A commentary on the 2015 Canadian Clinical Practice Guidelines in glutamine supplementation to parenteral nutrition
The author would like to issue an erratum for this article [1], and would like to declare the following competing interests which were inadvertently missed in the original publication. Competing interests I declare that I worked as an external freelance scientific consultant for Fresenius Kabi in Chile. My work has been limited to bibliographical analysis in the metabolic field non related with...
متن کاملRemoval of hepatocarcinoma cells from blood via cell washing and filtration techniques.
Utilization of autotransfusion during tumor resection remains controversial due to viability of carcinoma cells remaining in collected blood. The purpose of this study was to evaluate autotransfusion techniques combined with leukocyte depleting filters (LDF) for removal of hepatocarcinoma cells from autotransfusate. An in vitro model was created by contaminating expired human erythrocytes with ...
متن کاملA prospective comparison of the platelet sequestration ability of three autotransfusion devices.
Although current autotransfusion devices have platelet sequestration capabilities, each has a unique technology to achieve the final platelet product. The purpose of this study was to assess the quality and quantity of platelets sequestered by three different autotransfusion devices. The three commercially available autotransfusion devices evaluated were Fresenius C.A.T.S (closed spiral chamber...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 49 2 شماره
صفحات -
تاریخ انتشار 2017