New Algorithms for the Analysis of Waste Characterization

نویسندگان

  • Xiaoqin J. Guo
  • Richard. C. Hagenauer
چکیده

Nondestructive assay of gamma-ray emitting nuclear waste requires modeling because it is not practical to prepare a standard that matches the physical and nuclear properties of every waste item. The use of a high-purity germanium (HPGe) detector simplifies the spectral analysis process. Many models use simplified efficiency determinations and attenuation corrections. These models often work well for medium-sized items measured at detector-to-item distances that are at least half of the largest dimension of the object. Other models use a hybrid Monte Carlo approach, but the detector efficiency parameters must be established at an additional cost. A new algorithm has been developed to reduce these complications and limitations while retaining acceptable accuracy. This algorithm uses a simple mixed-nuclide gamma calibration, the detector crystal diameter and length, crystal type (n-type or p-type), thickness of the germanium dead layer, and distance from the top of the end cap to the germanium active layer to compute the detector intrinsic efficiency. The intrinsic efficiency for the front and side of the detector are correlated with the detector diameter and length. Corrections for the gamma rays from the item being measured are calculated voxel by voxel. These new algorithms have been implemented in the ORTEC ISOTOPIC software version 4. Results show significant improvement for items counted as close as 10 cm, and are useful for the measurement of items positioned in a low-level drum counter. INTRODUCTION When the detector is positioned close to a large item containing radioactivity a significant amount of activity enters the HPGe detector from the side. The classic far-field correction for matrix attenuation does not account for this because it assumes all gamma-rays enter the detector normal to the front surface. An algorithm has been developed that utilizes the crystal diameter and length to automatically estimate the efficiency of the detector from the side surface as well as the front surface. Only one point-source calibration, positioned normal to the front surface of the detector crystal, is needed. This point source, whose activity is traceable to a national standard, must contain gamma rays that span the energy range of the gamma rays emitted by the nuclides present in the measured item.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seasonal characterization and quantification of municipal solid waste: Energy content and statistical analysis

Determining the seasonal and annual quantities and compositions of the municipal solid waste and assessing the present management conditions of three urban communities in the northwest of Iran were the core objectives of this study. Our findings revealed that the average daily per capita of municipal waste generation was 0.489–0.841 kg/cap-day. Organic and food waste comprised the largest part ...

متن کامل

Preparation and Characterization of Diols and Polyols Based on Aminolysisof Poly (ethylene terephthalate) Wastes with Alkanolamines

The Plastic Waste phenomenon, which is the result of increasing poly (ethylene terephthalate) production and the wide range PET consumption in different industries, caused one of the major environmental concerns. Therefore,many different ways have been studied and applied for chemical recycling of PET. One of the most important ways to depolymerize poly (ethylene terephthalate) is the aminolysi...

متن کامل

Urban solid waste characterization in the east part of Black Sea region

In the current study, the solid waste characterisation that belongs to Artvin city centre, which is located in East Black Sea Region of Turkey, were searched. The study has the feature of being the first study for the country of Artvin in terms of study. The field of study is composed of 7 neighborhoods and those can be separated into 3 groups as low, middle and high level of income. In this st...

متن کامل

A New Method for Characterization of Biological Particles in Microscopic Videos: Hypothesis Testing Based on a Combination of Stochastic Modeling and Graph Theory

Introduction Studying motility of biological objects is an important parameter in many biomedical processes. Therefore, automated analyzing methods via microscopic videos are becoming an important step in recent researches. Materials and Methods In the proposed method of this article, a hypothesis testing function is defined to separate biological particles from artifact and noise in captured v...

متن کامل

Synthesis and characterization of the electrospun fibers prepared from waste polymeric materials

Recently, the demands for the production of many different types of plastic wastes are greatly growing that subsequently, lead to the serious challenges in environmental considerations. Since, these materials are rarely resolved by microorganisms, hence, their recycling to the useful materials is crucial. In the present study, we used a solution electrospinning technique to synthesize nano/micr...

متن کامل

Synthesis and characterization of the electrospun fibers prepared from waste polymeric materials

Recently, the demands for the production of many different types of plastic wastes are greatly growing that subsequently, lead to the serious challenges in environmental considerations. Since, these materials are rarely resolved by microorganisms, hence, their recycling to the useful materials is crucial. In the present study, we used a solution electrospinning technique to synthesize nano/micr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007