Temperature Measurements of Carbon Stripper Foil by Pulesd 650kev H- Ion Beam*

نویسندگان

  • A. Takagi
  • I. Sugai
  • Y. Irie
  • Y. Takeda
چکیده

Thick carbon foils (>300 mg/cm)has been used for stripping of H ion beam into protons at the injection stage of the 3GeV Rapid Cycling Synchrotron (3GeV-RCS) in J-PARC. The carbon stripper foils with high durability at high temperature >1800 oK are strongly required. A new irradiation system for foils is in progress using the KEK 650keV Cockcroft-Walton accelerator which can simulate the high-energy deposition upon foils in the RCS. The most important factor that affects the foil lifetime is the foil temperature. We are developing the measuring method of the temperature using a photo-transistor when a foil is irradiated by the short pulses with several tens ~ several hundreds microsecond durations. Preliminary results are described in this report.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Realization of Thick Hybrid Type Carbon Stripper Foils with High Durability at 1800k for Rcs of J-parc

The Japan-Proton Accelerator Research Complexes (J-PARC) requires thick carbon stripper foils (250-500 μg/cm) to strip electrons from the H beam supplied by the linac before injection into the RCS (Rapid Cycling Synchrotron). The 200 MeV H beam from the linac has a pulse length of 0.5 ms with a repetition rate of 25 Hz and an average beam current of 335 μA. For this high-energy and high-intensi...

متن کامل

Beam Injection and Extraction of Scent300, a Superconducting Cyclotron for Hadrontherapy

SCENT300 is a superconducting cyclotron able to deliver proton and carbon beam at 260 and 300 AMeV respectively. The simulations of the beam injection through the central region, the beam extraction through the electrostatic deflector for Carbon beam and by stripper foil for the proton beam are here presented.

متن کامل

Design of a 7 MeV/u, 217 MHz Injector Linac for Therapy Facilities

Design ion C (A/q = 3) Operating frequency 216.816 MHz Final beam energy 7 MeV/u Pulse currents after stripper ≈ 100 eμA C ≈ 0.7 mA protons Beam pulse length ≤ 200 μs @ ≤ 5 Hz Duty cycle ≤ 0.1 % Norm. transverse exit beam emittances (95%) 1 ≈ 0.8 π mm mrad Exit momentum spread 1 ±0.15 % Total injector length 2 ≈ 13 m 1 Not including emittance growth effects in the stripper foil. 2 Including the...

متن کامل

The Injector Systems of the Fair Project

The present GSI accelerator chain will serve as an injector for FAIR (Facility for Antiproton and Ion Research). The linear accelerator UNILAC and the heavy ion synchrotron SIS18 should deliver up to 1⋅10 U-particles/sec. In the past two years different hardware measures and a careful fine tuning of the UNILAC resulted in an 35% increase of the beam intensity to a new record of 1.25⋅10 U-ions...

متن کامل

Precise Atomic Lifetimes Measured at a Heavy-Ion Storage Ring

A new experimental technique, derived from beam-foil spectroscopy, has been developed for the measurement of long atomic lifetimes in ions. The ions are produced in a standard ion source and then, after a first acceleration step, collisionally excited in the gas or foil stripper of an accelerator. A beam of charge-state selected MeV-ions is transported to and then stored in the clean ultra-high...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008