Noninvasive measurement of cardiac output in hemodialysis patients by task force monitor: a comparison with the Transonic System.

نویسندگان

  • Thomas M Kitzler
  • Olga Sergeyeva
  • Alice Morris
  • Falko Skrabal
  • Peter Kotanko
  • Nathan W Levin
چکیده

Cardiovascular disease is the leading cause of morbidity and mortality in maintenance hemodialysis (MHD) patients. The Transonic (TRS; Transonic Systems, Ithaca, NY) device is frequently used for determination of cardiac output (CO) by an indicator dilution technique. The Task Force Monitor (TFM; CN Systems, Graz, Austria) has gained attention as noninvasive tool for continuous beat-to-beat assessment of cardiovascular variables, including CO by impedance cardiography. Despite its use in cardiology and intensive care settings, the TFM has yet not been validated in dialysis patients. This study compares CO measurements in 12 MHD patients by TFM and TRS. Bland-Altman and regression analysis were used. CO was measured simultaneously by TRS and TFM. Average CO was 5.4 L/min by TRS and 5.0 L/min by TFM, respectively. Bland-Altman analysis revealed no significant systematic differences between the two methods (mean difference: 0.4 L/min; SD: 0.6; p > 0.05). Linear regression analysis showed significant correlation between both techniques (r = 0.802, p = 0.002). The SD of mean individual CO values was 1.1 L/min with TRS and 0.8 L/min with TFM, respectively.CO measured by TFM and TRS does not differ significantly, thus making the TFM an attractive noninvasive tool for the continuous beat-to-beat assessment of CO in MHD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patients.

BACKGROUND Satisfactory haemodialysis (HD) vascular access flow (Qa) is necessary for dialysis adequacy. High Qa is postulated to increase cardiac output (CO) and cause high-output cardiac failure. Aim of the present prospective study was to evaluate the relationship between Qa of arteriovenous fistulas (AVFs) and CO in order to have a closer insight into this scarcely explored aspect of HD pat...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance.

STUDY OBJECTIVES Cardiac output (CO) is measured but sparingly due to limitations in its measurement technique (ie, right-heart catheterization). Yet, in recent years it has been suggested that CO may be of value in the diagnosis, risk stratification, and treatment titration of cardiac patients, especially those with congestive heart failure (CHF). We examine the use of a new noninvasive, conti...

متن کامل

Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP) poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from ...

متن کامل

ساخت و آزمون کارگاهی دینامومتر اتصال سه نقطه و چرخ پنجم سرعت سنج تراکتوری

For measuring draft force and drawbar power requirements for mounted implements, precise instruments such as three-point hitch dynamometers and tractor speed measurement devices are needed. In this research, a frame-type three-point hitch dynamometer was built and evaluated. Forces applied to dynamometer are measured by three separate load cells located on a frame which can be attached to tract...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ASAIO journal

دوره 53 5  شماره 

صفحات  -

تاریخ انتشار 2007