Moments generated during simulated rotational correction with self-ligating and conventional brackets.
نویسندگان
چکیده
OBJECTIVE To assess comparatively the magnitude of moments generated during rotational correction from different bracket systems during the late leveling and alignment stage of orthodontic treatment. MATERIALS AND METHODS The three types of brackets assessed were Orthos2 (ORMCO, Glendora, CA), Damon2 (ORMCO), and In Ovation-R (GAC, Bohemia, NY). The brackets were bonded on replicas made of resin from models constructed from an aligned patient's mandibular arch, and a 0.014- x 0.025-inch CuNiTi (ORMCO) wire was inserted. Orthodontic rotational correction was simulated on the Orthodontic Measurement and Simulation System from -5 degrees to +5 degrees rotation in 0.25 degrees increments on the distal and mesial direction. The moments generated at each increment of rotation throughout the full rotation path were statistically analyzed using a two-way analysis of variance and Tukey test at the .05 level of significance. RESULTS Both bracket type and direction of rotation showed an effect on moment magnitude. The highest moment (27.2 Nmm) was observed for the Damon2 bracket assigned to its noncompliant slot wall door. Higher moments were found during distal premolar rotation. The In Ovation-R showed a magnitude of moment in the range of 9.0 Nmm in the same direction, whereas conventional brackets presented the lowest moments (5.0 Nmm). CONCLUSIONS A wide variation in magnitude of moments exerted by self-ligating and conventional brackets is noted in the simulated rotational correction of teeth, which relates to the geometry of the dental arch, the tooth position, and the rigidity of the closing component of the bracket slot.
منابع مشابه
Comparative assessment of forces generated during simulated alignment with self-ligating and conventional brackets.
The objectives of this study were to comparatively assess the magnitude and direction of forces and moments generated from different bracket systems, during the initial levelling and alignment stage of orthodontic treatment. Three types of brackets were used: Orthos2 (Ormco), Damon2 (Ormco), and In-Ovation R (GAC). The brackets were bonded on resin replicas models of a patient's crowded mandibu...
متن کاملTorque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets.
The purpose of this research was to investigate the torque capacity of active and passive self-ligating brackets compared with metallic, ceramic, and polycarbonate edgewise brackets. Six types of orthodontic brackets were included in the study: the self-ligating Speed and Damon2, the stainless steel (SS), Ultratrimm and Discovery, the ceramic bracket, Fascination 2, and the polycarbonate bracke...
متن کاملEvaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets.
The purpose of this study was to compare the activation and deactivation forces generated during first-order archwire deflections when different sizes and types of NiTi wires are paired with conventional and self-ligating brackets (SLBs) and to evaluate the rotational control between these same archwire and bracket combinations. Four maxillary premolar SLBs (Damon 3MX, SmartClip, Carriere, and ...
متن کاملThird-order torque and self-ligating orthodontic bracket-type effects on sliding friction.
OBJECTIVE To examine the influence of third-order torque on kinetic friction in sliding mechanics involving active and passive self-ligating brackets. MATERIALS AND METHODS Wire-slot frictional forces were quantified and compared across five sets of brackets and tubes within a simulated posterior dental segment with -15 degrees , -10 degrees , -5 degrees , 0 degrees , +5 degrees , +10 degrees...
متن کاملA comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type
OBJECTIVE This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. METHODS Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Angle orthodontist
دوره 78 6 شماره
صفحات -
تاریخ انتشار 2008