Hypoglycemia Early Alarm Systems Based On Multivariable Models.

نویسندگان

  • Kamuran Turksoy
  • Elif S Bayrak
  • Lauretta Quinn
  • Elizabeth Littlejohn
  • Derrick Rollins
  • Ali Cinar
چکیده

Hypoglycemia is a major challenge of artificial pancreas systems and a source of concern for potential users and parents of young children with Type 1 diabetes (T1D). Early alarms to warn the potential of hypoglycemia are essential and should provide enough time to take action to avoid hypoglycemia. Many alarm systems proposed in the literature are based on interpretation of recent trends in glucose values. In the present study, subject-specific recursive linear time series models are introduced as a better alternative to capture glucose variations and predict future blood glucose concentrations. These models are then used in hypoglycemia early alarm systems that notify patients to take action to prevent hypoglycemia before it happens. The models developed and the hypoglycemia alarm system are tested retrospectively using T1D subject data. A Savitzky-Golay filter and a Kalman filter are used to reduce noise in patient data. The hypoglycemia alarm algorithm is developed by using predictions of future glucose concentrations from recursive models. The modeling algorithm enables the dynamic adaptation of models to inter-/intra-subject variation and glycemic disturbances and provides satisfactory glucose concentration prediction with relatively small error. The alarm systems demonstrate good performance in prediction of hypoglycemia and ultimately in prevention of its occurrence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hypoglycemia early alarm systems based on recursive autoregressive partial least squares models.

BACKGROUND Hypoglycemia caused by intensive insulin therapy is a major challenge for artificial pancreas systems. Early detection and prevention of potential hypoglycemia are essential for the acceptance of fully automated artificial pancreas systems. Many of the proposed alarm systems are based on interpretation of recent values or trends in glucose values. In the present study, subject...

متن کامل

Artificial Pancreas Systems: An Integrated Multivariable Adaptive Approach

An artificial pancreas (AP) system with a hypoglycemia early alarm system and adaptive control system based on multivariable recursive time series models is developed. The inputs of the model include glucose concentration (GC) and physiological signals that provide information about the physical activities and stress of the patient. The stability of the recursive time-series models is guarantee...

متن کامل

Hypoglycemia alarm enhancement using data fusion.

BACKGROUND The acceptance of closed-loop blood glucose (BG) control using continuous glucose monitoring systems (CGMS) is likely to improve with enhanced performance of their integral hypoglycemia alarms. This article presents an in silico analysis (based on clinical data) of a modeled CGMS alarm system with trained thresholds on type 1 diabetes mellitus (T1DM) patients that is augmented by sen...

متن کامل

Hypoglycemia prediction with subject-specific recursive time-series models.

BACKGROUND Avoiding hypoglycemia while keeping glucose within the narrow normoglycemic range (70-120 mg/dl) is a major challenge for patients with type 1 diabetes. Continuous glucose monitors can provide hypoglycemic alarms when the measured glucose decreases below a threshold. However, a better approach is to provide an early alarm that predicts a hypoglycemic episode before it occurs, allowin...

متن کامل

Hypoglycemia detection in critical care using continuous glucose monitors: an in silico proof of concept analysis.

BACKGROUND Tight glycemic control (TGC) in critical care has shown distinct benefits but has also been proven difficult to obtain. The risk of severe hypoglycemia (<40 mg/dl) has been increased significantly in several, but not all, studies, raising significant concerns for safety. Continuous glucose monitors (CGMs) offer frequent measurement and thus the possibility of using them for early det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial & engineering chemistry research

دوره 52 35  شماره 

صفحات  -

تاریخ انتشار 2013