Characteristics of a pMOSFET suitable for use in radiotherapy.

نویسندگان

  • Svetlana Pejovic
  • Petar Bosnjakovic
  • Olivera Ciraj-Bjelac
  • Momcilo M Pejovic
چکیده

The paper describes dose response and signal fading of Al-gate p-channel (metal oxide semiconductor field effect transistors) MOSFETs in the range of gamma radiation doses used in radiation therapy. MOSFETs with thicknesses of the gate oxide layer of 1 μm and 400 nm were used. The response was characterized by the threshold voltage shift and was studied as a function of the absorbed dose and time after irradiation. The dosimeters with the 1-μm-thick oxide layer can be effectively used for measuring doses in the 0.1-5 Gy range. The dosimeters with 400-nm-thick oxide layer are suitable for measuring doses above 5 Gy. Both types of the dosimeters retain dosimetric information for long periods of time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Characteristics of Transparent Bolus for External Beam Radiotherapy

Introduction: In radiotherapy, the bolus is often used while treating the tumor under the uneven surfaces of the patients for correcting the anatomical irregularities and increasing skin dose. Wet cotton and wet gauze are still used in developing countries, since the use of wet cotton and wet gauze has certain disadvantages, there is a need for transparent bolus which ...

متن کامل

Investigation of Single pMOSFET Gate Oxide Degradation on NOR Logic Circuit Operability

The impact of gate oxide degradation of a single pMOSFET on the performance of the CMOS NOR logic circuit has been examined using a switch matrix technique. A constant voltage stress of -4.0V was used to induce a low level of degradation to the 2.0nm gate oxide of the pMOSFET. Characteristics of the CMOS NOR logic circuit following gate oxide degradation are analyzed in both the DC and V-t doma...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

Use of gold nanoparticles in MAGIC-f gels to 18 MeV photon enhancement

Objective(s): Normoxic MAGIC-f polymer gels are established dosimeters used for three dimensional dose quantifications in radiotherapy. Nanoparticles with high atomic number such as gold are novel radiosensitizers used to enhance doses delivered to tumors. The aim of this study was to investigate the effect of gold nanoparticles (GNPs) in enhancing percentage depth doses (PDDs) within the MAGIC...

متن کامل

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 77  شماره 

صفحات  -

تاریخ انتشار 2013