Normal values and reproducibility of the real-time index of vagal tone in healthy humans: a multi-center study

نویسندگان

  • Adam D. Farmer
  • Steven J. Coen
  • Michiko Kano
  • Nathalie Weltens
  • Huynh Giao Ly
  • Claude Botha
  • Peter A. Paine
  • Lukas Van Oudenhove
  • Qasim Aziz
چکیده

BACKGROUND The parasympathetic nervous system has been implicated in the pathogenesis of a number of gastrointestinal disorders including irritable bowel syndrome. Within the field, cardiometric parameters of parasympathetic/vagal tone are most commonly derived from time, or frequency, domain analysis of heart rate variability (HRV), yet it has limited temporal resolution. Cardiac vagal tone (CVT) is a non-invasive beat-to-beat measure of brainstem efferent vagal activity that overcomes many of the temporal limitations of HRV parameters. However, its normal values and reproducibility in healthy subjects are not fully described. The aim of this study was to address these knowledge gaps. METHODS 200 healthy subjects (106 males, median age 28 years, range 18-59 years) were evaluated across three study centers. After attachment of CVT recording equipment, 20 min of data (resting/no stimulation) was acquired. 30 subjects, selected at random, were restudied after 1 year. RESULTS The mean CVT was 9.5±4.16 linear vagal scale (LVS). Thus, the normal range (mean±2 standard deviations) for CVT based on this data was 1.9-17.8 LVS. CVT correlated negatively with heart rate (r=-0.6, P=0.001). CVT reproducibility over 1 year, as indexed by an intra-class correlational coefficient of 0.81 (95% confidence interval 0.64-0.91), was good. CONCLUSIONS In healthy subjects, the normal range for CVT should be considered to be 1.9-17.8 LVS and is reproducible over 1 year. Future research utilizing CVT should refer to these values although further study is warranted in patient groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time measurement of cardiac vagal tone in conscious dogs.

Rapid changes in heart rate are caused by changes in parasympathetic tone. The NeuroScope is an electronic device designed to offer an objective real-time measure of instantaneous cardiac vagal tone by phase demodulation of a high-resolution time domain of R-R wave intervals. Data are displayed against an arbitrary but linear scale, the cardiac index of parasympathetic activity (CIPA). To valid...

متن کامل

Assessment of air quality index in proximity of Bandar Abbas oil refinery

Introduction: Air pollution is one of the most important problems in recent century, which threats humans' health. This study was conducted to assess air pollution with respect to PM10, SO2, CO, NO2, H2S, and Air Quality Index (AQI), in a location in close proximity to Bandar Abbas oil refinery. Methods: In this study a location in close proximity to Bandar Abbas oil refinery was selecte...

متن کامل

Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran

Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic center in Guilan in northern Iran. Materials and Methods: Fifty-five people presenting to a teach...

متن کامل

Acoustic Sensitivity of the Saccule and Daf Music

  Introduction:   The daf is a large Persian frame drum used as a musical instrument in both popular and classical music which can induce a percussive sound at low frequencies (146–290 Hz) with peaks of up to 130 dBspl. The percussive sounds have a power distribution in the region of saccular sensitivity. In view of the saccular stimulation by sound in humans, we decided to use cervical vestibu...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2014