Dosimetry Verification of 125I Seeds Implantation With Three-Dimensional Printing Noncoplanar Templates and CT Guidance for Paravertebral/Retroperitoneal Malignant Tumors

نویسندگان

  • Zhe Ji
  • Yuliang Jiang
  • Liang Su
  • Fuxin Guo
  • Ran Peng
  • Haitao Sun
  • Jinghong Fan
  • Junjie Wang
چکیده

OBJECTIVE To compare dose distributions of postoperative plans with preoperative plans for radioactive seed implantation of paravertebral/retroperitoneal tumors assisted by 3-dimensional printing noncoplanar templates and computed tomography. METHODS Sixteen patients with paravertebral/retroperitoneal tumors (21 lesions) underwent radioactive seed implantation with 3-dimensional printing noncoplanar templates. Prescribed dose was 110 to 160 Gy. We compared the dose distribution of the postoperative plan with the preoperative plan. Dose parameters were D90, minimum peripheral dose, V100, V150, conformal index and external index of the target volume, and the dose received by 2 cm3 of normal tissue of organs at risk (spinal cord, aorta, and kidney). RESULTS Sixteen 3-dimensional printing noncoplanar templates were produced for 21 treatment areas. Mean gross tumor volume (preoperative) of patients was 61.1 cm3, mean needle number was 17, mean number of implanted 125I seeds was 65, and mean D90 of postoperative target area (gross tumor volume) was 131.1 Gy. Actual number of seeds postbrachytherapy increased by 1 to 12 in 8 cases. For postoperative plans, the mean D90, minimum peripheral dose, V100, V150 was 131.1 Gy, 67.1 Gy, 90.2%, and 64.1%, respectively, and 135.0 Gy, 64.7 Gy, 90.9%, and 64.1%, respectively, in preoperative plans. Comparing with the preplanned cases, the dose of the target volume was slightly lower and the high-dose area of the target volume was larger in postoperative cases, but the difference was not statistically significant ( P > .05). Actual dose conformity of the target volume was lower than preplanned, and the difference was statistically significant ( P = .005). CONCLUSION Three-dimensional printing noncoplanar templates can provide good accuracy for positioning and direction in radioactive seed implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors

OBJECTIVE To explore the therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors. MATERIALS AND METHODS Fifteen liver cancer patients with 47 total lesions were treated with 3-D printing template-assisted radioactive seed implantation (group A), and 25 liver-tumor patients with 66 total lesions were treated with 125I-seed implantat...

متن کامل

A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neck

To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Be...

متن کامل

Computed tomography-guided implantation of 125I seeds brachytherapy for recurrent multiple pulmonary oligometastases: initial experience and results

PURPOSE To retrospectively evaluate the efficacy and safety of computed tomography (CT)-guided percutaneous interstitial brachytherapy using 125I radioactive seeds for multiple pulmonary metastatic tumors. MATERIAL AND METHODS Between September 2013 and December 2015, 22 patients with multiple pulmonary metastases, who after conventional chemotherapy and trans-arterial chemoembolization (TACE...

متن کامل

Three-dimensional verification of 125I seed stability after permanent implantation in the parotid gland and periparotid region

OBJECTIVE To evaluate seed stability after permanent implantation in the parotid gland and periparotid region via a three-dimensional reconstruction of CT data. MATERIAL AND METHODS Fifteen patients treated from June 2008 to June 2012 at Peking University School and Hospital of Stomatology for parotid gland tumors with postoperative adjunctive (125)I interstitial brachytherapy were retrospect...

متن کامل

Side effects of CT-guided implantation of 125I seeds for recurrent malignant tumors of the head and neck assisted by 3D printing non co-planar template

BACKGROUND For the recurrence of head and neck cancer after operation and radiotherapy, the local control of radioactive seed implantation is good, and it has a certain palliative effect. This study aims to investigate the acute and late side effects of a three-dimentional printing non co-planar template (3D-PNCT) for computed tomography (CT)-guided radioactive 125I seed (RIS) implantation in r...

متن کامل