Thorax, pelvis and hip pattern in the frontal plane during walking in unilateral transtibial amputees: biomechanical analysis

نویسندگان

  • Francisco Molina-Rueda
  • Isabel M. Alguacil-Diego
  • Alicia Cuesta-Gómez
  • Javier Iglesias-Giménez
  • Andrés Martín-Vivaldi
  • Juan C. Miangolarra-Page
چکیده

BACKGROUND Lower limb amputees exhibit postural control deficits during standing which can affect their walking ability. OBJECTIVES The primary purpose of the present study was to analyze the thorax, pelvis, and hip kinematics and the hip internal moment in the frontal plane during gait in subjects with Unilateral Transtibial Amputation (UTA). METHOD The participants included 25 people with UTA and 25 non-amputees as control subjects. Gait analysis was performed using the Vicon(r) Motion System. We analyzed the motion of the thorax, pelvis, and hip (kinematics) as well as the hip internal moment in the frontal plane. RESULTS The second peak of the hip abductor moment was significantly lower on the prosthetic side than on the sound side (p=.01) and the control side (right: p=.01; left: p=.01). During middle stance, the opposite side of the pelvis was higher on the prosthetic side compared to the control side (right: p=.01: left: p=.01). CONCLUSIONS The joint internal moment at the hip in the frontal plane was lower on the prosthetic side than on the sound side or the control side. Thorax and pelvis kinematics were altered during the stance phase on the prosthetic side, presumably because there are mechanisms which affect postural control during walking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Analysis of the Influence of SACH Foot and Dynamic-Response Foot in Individual With Unilateral Transtibial Amputee During Running

Objective: Amputation of the lower limb due to loss of part of the musculoskeletal structure reduces performance and increases injury during locomotion. The effect of various types of prosthetic feet has been analyzed in several studies during running. The purpose of this study was a biomechanical analysis of the influence of SACH and Dynamic-Response foot on several kinetic variables in the st...

متن کامل

Assessment of Dynamic Stability During Walking in Below-knee Amputation

Purpose: Dynamic stability reduces in patients with unilateral amputation; so, it is important to recognize changes in balance during walking. This study aimed to investigate the dynamic stability of unilateral below-knee amputation during walking. Methods: The present study was a quasi-experimental study, in which 10 patients with knee amputation and 10 healthy young people participated. The ...

متن کامل

Uphill and downhill walking in unilateral lower limb amputees.

OBJECTIVE To study adjustment strategies in unilateral amputees in uphill and downhill walking. DESIGN Observational cohort study. SUBJECTS Seven transfemoral, 12 transtibial unilateral amputees and 10 able-bodied subjects. METHODS In a motion analysis laboratory the subjects walked over a level surface and an uphill and downhill slope. Gait velocity and lower limb joint angles were measu...

متن کامل

The effects of prosthetic foot stiffness on transtibial amputee walking mechanics and balance control during turning.

BACKGROUND Little evidence exists regarding how prosthesis design characteristics affect performance in tasks that challenge mediolateral balance such as turning. This study assesses the influence of prosthetic foot stiffness on amputee walking mechanics and balance control during a continuous turning task. METHODS Three-dimensional kinematic and kinetic data were collected from eight unilate...

متن کامل

Interlimb symmetry of traumatic unilateral transtibial amputees wearing two different prosthetic feet in the early rehabilitation stage.

This study evaluated the SACH and the Greissinger Plus prosthetic feet, in terms of the symmetry provided between the lower limbs, in the case of unilateral transtibial amputees 16.3 weeks from the time of limb fitting and 38.9 weeks from surgery. Sagittal plane gait analysis was carried out for nine right-limb traumatic amputees. In all examined cases, the spatial and temporal parameters measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2014