Analysis of degradation products of chemical warfare agents using capillary electrophoresis.

نویسندگان

  • Svetlana S Aleksenko
  • Pierre Gareil
  • Andrei R Timerbaev
چکیده

Analysis of chemical warfare agents (CWAs), their precursors and degradation products (DPs) is an important verification component in support of the Chemical Weapons Convention and urgently demanding rapid and reliable analytical methods. Considering a growing number of papers presented in the last years in the field of capillary electrophoresis (CE) of DPs, this review article gives an overview on CE techniques which are feasible for the determination of DPs with the advantages of using relatively simple and inexpensive research instrumentation, reduced consumption of potentially toxic samples, shorter sample preparation times, etc. A brief introduction is provided into the chemical background of CWAs followed by a documented appraisal that the CE method is well suited to deal with polar, acidic DPs mostly occurring in aqueous samples or extracts. Applications of CE to the separation of DPs are described, complemented by a critical discussion of the detection techniques, including mostly conductivity, laser-induced fluorescence, UV absorption and mass spectrometry. This review also includes actual development regarding the challenges of CE in analyses of different DPs from real samples, often avoided by in- and off-line pre-concentration techniques or the coupling of CE to selective detection methods. Special emphasis is placed on the miniaturised CE systems that have the potential of being before long developed into a field deployable and potentially disposable platform for routine DP monitoring in environmental samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CE–MS-MS for the Identification of Chemical Warfare Agent Degradation Products

Please direct correspondence to Pierre Gareil at [email protected]. he different conflicts of the 20th century were marked by the use of chemical weapons. Therefore, the Chemical Weapons Convention (CWC) was signed in 1993 and came into force in 1997 to prohibit the development, production, stockpiling, and use of chemical warfare agents (1). But today, the use of chemical weapons by terro...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

Non-Aqueous Electromigration Analysis of Some Degradation Products of Carvedilol

A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...

متن کامل

Non-Aqueous Electromigration Analysis of Some Degradation Products of Carvedilol

A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 136 20  شماره 

صفحات  -

تاریخ انتشار 2011