A Study of the Arterial Clearance of Xenon 133 in Man.
نویسندگان
چکیده
Arterial xenon 133 concentrations have been measured after inhalation of the isotope in anaesthetized and conscious human patients. The anaesthetized patients were ventilated by either a mechanical or a manual method. The arterial concentration of xenon 133 was compared with the pulmonary radioactivity measured by external scintillation counting during clearance of the gas. The rates of arterial clearance of xenon 133 were expressed as the length of time taken to fall to 10 per cent of the original level of radioactivity. In the control group this value was 3.5 minutes. Pulmonary external scintillation counting did not reflect the concentration of arterial xenon 133 accurately. The significance of these findings was discussed with particular reference to the determination of cerebral blood flow.
منابع مشابه
Cerebral circulation studies using inhaled 133-xenon and the gamma camera.
Cerebral Circulation Studies Using Inhaled 133-Xenon and the Gamma Camera • Inhaled 133-xenon was utilized in conjunction with the Anger gamma scintillation camera to evaluate cerebral circulation in 20 asymptomatic control subjects and in 41 patients with clinical cerebrovascular disease. Sequental cerebral scintiphotos thus obtained revealed focal areas of decreased activity in 2 of 19 contro...
متن کاملMUSCLE BLOOD FLOW DURING EXERCISE In patients suffering from intermittent claudication,
Pathophysiological considerations predict that exercise blood flows at comparable work loads must always be reduced in claudicants in comparison to normal subjects. The present study verified that the exercise blood flow determined by 133xenon clearance measurements in the gastrocnemius muscle in claudicants and in a control group differed widely. As expected, a statistically significant correl...
متن کاملMUSCLE BLOOD FLOW DURING EXERCISE In patients suffering from intermittent claudication,
Pathophysiological considerations predict that exercise blood flows at comparable work loads must always be reduced in claudicants in comparison to normal subjects. The present study verified that the exercise blood flow determined by 133xenon clearance measurements in the gastrocnemius muscle in claudicants and in a control group differed widely. As expected, a statistically significant correl...
متن کاملComparison of the effects of atenolol, sotalol and labetalol on muscle blood flow in man.
A double-blind study of the effect of three beta-adrenoceptor blocking drugs (beta-blockers) on exercise muscle blood flow (MBF) in 14 normotensive volunteers was carried out. MBF was measured by the xenon-133 clearance technique. MBF was not altered by placebo, sotalol or labetalol. Atenolol significantly reduced MBF compared with placebo, sotalol and labetalol. We conclude that sotalol and la...
متن کاملQuantitation of mitral regurgitation by constant infusion of xenon-133.
A method for the accurate quantitation of mitral regurgitation in man was Gescribed and tested in 23 patients. The technique involves a constant infusion of xenon-133 into the left ventricle for 2 minutes. Left atrial and arterial samples must be withdrawn after constant concentration is achieved and before recirculation reaches high values. It was shown that concentration of indicator at both ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 37 شماره
صفحات -
تاریخ انتشار 1965