Comparison between Anterior Corneal Aberration and Ocular Aberration in Laser Refractive Surgery

نویسندگان

  • Jong Mi Lee
  • Dong Jun Lee
  • Woo Jin Jung
  • Woo Chan Park
چکیده

PURPOSE To compare changes of anterior corneal aberration (Pentacam) and ocular aberration (aberrometer, LADARWave) after laser refractive surgery. METHODS Sixty-six eyes underwent laser refractive surgery and were retrospectively reviewed. Anterior corneal aberration and ocular aberration were measured by Pentacam and an aberrometer (LADARWave) respectively. Changes of root mean square (RMS) values of coma, spherical aberration, and total high order aberration (HOA) were evaluated before, 1 month, and 3 months after surgery RESULTS Ocular aberrations displayed low preoperative values, but after laser refractive surgery, anterior corneal aberration and ocular aberration increased equally. There were no statistically significant differences of internal optics aberration values (ocular aberration minus anterior corneal aberration) in coma, spherical aberration, and total HOA. Anterior corneal aberration and ocular aberration showed statistically significant correlations at 1 and 3 months after surgery. CONCLUSIONS Internal optics aberration compensated the anterior corneal aberration effectively before surgery, but the increase of anterior corneal aberration after laser refractive surgery exceeded the compensation of internal optics. As a result, anterior corneal aberration and ocular aberration increased equally. The correlation between anterior corneal aberration and ocular aberration after surgery was statistically significant due to the increased proportion of anterior corneal aberration in ocular aberration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical response to LASIK surgery for myopia from total and corneal aberration measurements.

PURPOSE To evaluate the optical aberrations induced by LASIK refractive surgery for myopia on the anterior surface of the cornea and the entire optical system of the eye. METHODS Total and corneal aberrations were measured in a group of 14 eyes (preoperative myopia ranging from -2.5 to -13 D) before and after LASIK surgery. Total aberrations were measured using a laser ray-tracing technique. ...

متن کامل

Causes of spherical aberration induced by laser refractive surgery.

PURPOSE To develop a corneal model to better explain how refractive surgery procedures induce spherical aberration. SETTING Department of Ophthalmology and Center for Visual Science, University of Rochester, Rochester, New York, USA. METHODS The preoperative cornea was modeled as a rotationally symmetric surface with various radii of curvature and asphericities. The postoperative cornea was...

متن کامل

Comparison of real and computer-simulated outcomes of LASIK refractive surgery.

Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were co...

متن کامل

Comparison of corneal and total ocular aberrations before and after myopic LASIK.

PURPOSE To assess the compensation of total ocular and corneal wavefront aberrations after conventional myopic LASIK. METHODS This study comprised 57 eyes of 57 patients. Total and corneal aberrations were measured preoperatively and 3 months postoperatively using the OPD-Scan (NIDEK Co Ltd) aberrometer. Total and corneal aberrations root-mean-square (RMS) was calculated out to the 6th Zernik...

متن کامل

Aberrations and visual performance following standard laser vision correction.

PURPOSE To relate the change of ocular aberrations with the change of visual performance produced by standard laser in situ keratomileusis (LASIK) for myopia. METHODS Aberrations and visual performance were measured before and after surgery in 22 eyes. Total aberrations were measured using a laser ray tracing technique. Corneal aberrations were obtained using a commercial videokeratoscope and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2008