Progress on Fabric Electrodes Used in Biological Signal Acquisition

نویسندگان

  • Zhen Liu
  • Xiaoxia Liu
  • Z. Liu
  • X. X. Liu
چکیده

Due to its convenience, wear ability, affinity, continuously monitoring biological signal, etc., fabric electrodes used in biological signal acquisition attracted more and more interest from researchers around the world. Fabric electrode is a kind of intelligent textiles, and its application is very prominent in biological signal acquisition, supercapacitors and ECG (electric signal) monitoring. There are many methods that can be used to prepare fabric electrodes. They are mainly metal plating, conductive polymer coating, magnetron sputtering, and gas phase deposition and impregnation. Besides, they select the appropriate substrate, conductive medium and composite way to get light fabric electrodes which have high conductivity and good conformability. Since the conductive properties of conductive polymers are weaker than those of metal, conductive polymer must undergo protonic acid doping. They can be polythiophene, polypyrrole, polyaniline, etc. However, at present, researchers commit more studies to metal or carbon-based electrodes. For example, a layer of silver film is platted on the fabric by magnetron sputtering to increase its conductivity. In this paper, the development of fabric electrodes was studied from several aspects, namely, the generation of biological signals, the overall design of the wearable monitoring systems, its classification, conductive principles, preparation of fabric electrode and application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Progress on Fabric Electrodes Used in ECG Signals Monitoring

Wearable monitoring system is designed for skin stimulation of conductive adhesive, prolonged physiological monitoring and biocompatibility, whose core is fabric electrodes and it can feedback physiological status by analysis of abnormal electrocardiogram (ECG). Fabric electrode is a sensor to collect biological signals based on textile materials including signals acquisition, processing system...

متن کامل

ساخت حسگر پارچه‌ای سیگنال قلب توسط چاپ و لایه نشانی فلز مس روی پارچه پلی‌استر

In the last decade, a significant progress has been made in the wearable medical devices. Scientists are extensively involved in the design of the flexible instruments equipped with garments to fulfill the daily needs and requirements. The fulfillment of this demand particularly needs a conductive fabric substrate with a high level of homogeneity, and the lowest barrier against electrical curre...

متن کامل

WEALTHY – a wearable healthcare system: new frontier on e-textile

A comfortable health monitoring system named WEALTHY is presented. The system is based on a wearable interface implemented by integrating fabric sensors, advanced signal processing techniques and modern telecommunication systems, on a textile platform. Conducting and piezoresistive materials in form of fibre and yarn are integrated in a garment and used as sensors, connectors and electrode elem...

متن کامل

Electrical performance of PEDOT:PSS-based textile electrodes for wearable ECG monitoring: a comparative study

BACKGROUND Wearable textile electrodes for the detection of biopotentials are a promising tool for the monitoring and early diagnosis of chronic diseases. We present a comparative study of the electrical characteristics of four textile electrodes manufactured from common fabrics treated with a conductive polymer, a commercial fabric, and disposable Ag/AgCl electrodes. These characteristics will...

متن کامل

Interpretation of Electrochemical Noise Signals Arising from Symmetrical and Asymmetrical Electrodes Made of Polypyrrole Coated Mild Steel

This article applies the standard deviation of partial signal (SDPS) plots of electrochemical noise (EN) current signals originating from corrosion events on the symmetrical and asymmetrical electrodes made of uncoated and polypyrrole (PPy)-coated mild steel alloy in 4000 ppm NaCl+1000 ppm NaNO2 solution. Signal recording was performed after 30, 60, 90 min and 24 h from immersion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015