Quantitative myocardial mapping of perfusion and metabolism using parametric polar map displays in cardiac PET.
نویسندگان
چکیده
UNLABELLED Most efficacy studies of cardiac PET in demonstrating myocardial ischemia and viability have been performed using one or more transversal static images of the heart. In contrast, in this paper we describe a method of functional imaging of the complete left ventricular myocardium for perfusion with nitrogen-13-ammonia, both at rest and during a dipyridamol stress test, and of glucose metabolism with 18F-fluorodeoxyglucose (18FDG). METHODS This was performed by using the data of each of 48 radial segments of 10 short-axis images as tissue data and LV cavity data of three basal planes as blood pool data. The study describes the results of 19 normal volunteers and 36 patients with coronary artery disease. From the data of the normal volunteers a 95% normal confidence interval was calculated for each imaging modality. These intervals were then used to describe the patient data as normal, ischemic or infarcted. RESULTS The results of analysis of the parametric images was compared with the results of static analysis of the same patient data and found to be less dependant on the detection threshold used. CONCLUSION The described method enables the routine application of functional PET imaging of the total myocardium by the semi-automatic construction of parametric flow and metabolism polar maps. It thus provides an increased performance in the diagnosis, quantification and localization of myocardial ischemia and viability over conventional PET imaging.
منابع مشابه
Myocardial perfusion SPECT: Perfusion quantification
Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically. Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...
متن کاملDifferential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms
Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...
متن کاملAdvances in parametric mapping with CMR imaging.
Cardiac magnetic resonance imaging (CMR) is well established and considered the gold standard for assessing myocardial volumes and function, and for quantifying myocardial fibrosis in both ischemic and nonischemic heart disease. Recent developments in CMR imaging techniques are enabling clinically-feasible rapid parametric mapping of myocardial perfusion and magnetic relaxation properties (T1, ...
متن کاملMeasuring the expansion of myocardial extracellular volume using quantitative perfusion imaging: Validation with T1 mapping and simultaneous 18FDG-PET in patients after acute myocardial infarction
Background Expansion of myocardial extracellular volume (ECV) as detected by native and post contrast T1 mapping has been associated with different types of cardiomyopathy. We hypothesize that fully quantitative evaluation of MR perfusion imaging can localize and quantify edematous ECV expansion after acute coronary events with sensitivity equivalent to ECV measurements based on T1 mapping or t...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 36 1 شماره
صفحات -
تاریخ انتشار 1995