Consensus on recording of gas permeable contact lens fit.
نویسندگان
چکیده
PURPOSE To develop a new schematic scheme for efficiently recording the key parameters of gas permeable contact lens (GP) fits based on current consensus. METHODS Over 100 established GP fitters and educators met to discuss the parameters proposed in educational material for evaluating GP fit and concluded on the key parameters that should be recorded. The accuracy and variability of evaluating the fluorescein pattern of GP fit was determined by having 35 experienced contact lens practitioners from across the world, grading 5 images of a range of fits and the topographer simulation of the same fits, in random, order using the proposed scheme. The accuracy of the grading was compared to objective image analysis of the fluorescein intensity of the same images. RESULTS The key information to record to adequately describe the fit of an GP was agreed as: the manufacturer, brand and lens parameters; settling time; comfort on a 5 point scale; centration; movement on blink on a ±2 scale; and the Primary Fluorescein Pattern in the central, mid-peripheral and edge regions of the lens averaged along the horizontal and vertical lens axes, on a ±2 scale. On average 50-60% of practitioners selected the median grade when subjectively rating fluorescein intensity and this was correlated to objective quantification (r=0.602, p<0.001). Objective grading suggesting horizontal median fluorescein intensity was generally symmetrical, as was the vertical meridian, but this was not the case for subjective grading. Simulated fluorescein patterns were subjectively and objectively graded as being less intense than real photographs (p<0.01). CONCLUSION GP fit recording can be standardised and simplified to enhance GP practice.
منابع مشابه
Visual rehabilitation with new-age rigid gas-permeable scleral contact lenses--a case series.
INTRODUCTION Primary ectatic corneal diseases usually require rigid gas-permeable (RGP) corneal contact lens wear for visual rehabilitation. As the disease progresses, it becomes increasingly difficult to fit these lenses. RGP scleral contact lenses now provide another treatment option before resorting to surgery. CLINICAL PICTURE Two patients with pellucid marginal degeneration and one with ...
متن کامل[Contact lens in children: epidemiological aspects].
PURPOSE To describe the epidemiology of children submitted to contact lens fit. METHODS Retrospective study of 73 children that had been submitted to contact lens fit at the "Universidade Federal de São Paulo". This study analyzed sex distribution, age, diagnosis, indications and contact lens fitted at first examination. RESULTS 34 children (46.6%) were male and 39 (53.4%) female, aged betw...
متن کاملOptimal time following fluorescein instillation to evaluate rigid gas permeable contact lens fit.
PURPOSE To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6 ± 1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the ...
متن کاملContact lens rehabilitation following repaired corneal perforations
BACKGROUND Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. METHOD Eyes that had undergone repair for corneal perforating injuries with or wit...
متن کامل[Rigid gas permeable contact lenses fitted in a case of congenital glaucoma].
CASE REPORT A 27-year-old woman with congenital glaucoma with high myopia, low visual acuity and nystagmus in both eyes, was referred for contact lens fitting. We fitted her with aspherical rigid gas permeable (RGP) contact lenses with high transmissibility, which she wore on a daily basis. Her visual acuity improved with the wearing of these lenses, which remained comfortable whilst being worn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Contact lens & anterior eye : the journal of the British Contact Lens Association
دوره 36 6 شماره
صفحات -
تاریخ انتشار 2013