Photoelastic determination of polymerization shrinkage stress in low-shrinkage resin composites.

نویسندگان

  • Inga Rullmann
  • Anke Schattenberg
  • Miriam Marx
  • Brita Willershausen
  • Claus-Peter Ernst
چکیده

Low-shrinkage resin composites are in the focus of research in posterior resin composite restoratives. The aim of the study was to examine the polymerization shrinkage stress of new composites (Venus Diamond/ Heraeus Kulzer; SDR/DENTSPLY) and an experimental low-shrinkage resin composite (Ormocer/VOCO) in comparison to established low-shrinkage resin composites (Filtek Silorane/ 3M ESPE; els/Saremco; Filtek Supreme XT/3M ESPE; Clearfil Majesty Posterior/Kuraray). Cylindrical cavities (∅ 4 mm) in Araldit-B epoxy resin plates (40×40×4 mm) were pretreated with the Rocatec system to ensure bonding of the resin composites. The resin composite specimens (n = 10) were exposed to light for 60 s with a QTH curing device (Translux energy, Heraeus Kulzer, Germany). The samples were stored dark and dry (23 °C). Polymeri-zation shrinkage stress data (MPa) 4 min and 24 h post exposure were calculated based on the diameter of the first-order isochromatic rings, obtained from the Araldit plates. The statistical analysis of the obtained data was carried out with the Wilcoxon test (p = 0.05). After 24 h, the following mean stress values and standard deviations were obtained: Venus Diamond 3.4 ± 0.27 MPa; SDR 3.3 ± 0.26 MPa; exp. Ormocer 4.0 ± 0.18 MPa; Filtek Silorane 2.8 ± 0.19 MPa; els 2.5 ± 0.09 MPa; Filtek Supreme XT 6.0 ± 0.20 MPa; and Clearfil Majesty Posterior 5.6 ± 0.15 MPa. For all materials, higher polymerization stress values were recorded after 24 h. All differences in the shrinkage data obtained after 24 h were statistically significant (p < 0.05) except Venus Diamond/SDR. Venus Diamond, els and SDR showed shrinkage data closer to that of Filtek Silorane.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

انقباض پلیمریزاسیون در کامپوزیت‌های حاوی سیلوران و متاکریلات با دستگاه‌های تابشی LED با شدت‌های مختلف

Background and Aims: Polymerization shrinkage in Methacrylate-based composite is one of the most important factors in composite restorations failure. Silorane-based composite is introduced to compensate this drawback and claimed to have low shrinkage. The aim of this study was to evaluate the polymerization shrinkage of these two composites. Materials and Methods: In this experimental study, 5...

متن کامل

The Influence of Water Sorption of Dental Light-Cured Composites on Shrinkage Stress

The contraction stress generated during the photopolymerization of resin dental composites is the major disadvantage. The water sorption in the oral environment should counteract the contraction stress. The purpose was to evaluate the influence of the water sorption of composite materials on polymerization shrinkage stress generated at the restoration-tooth interface. The following materials we...

متن کامل

Photoelastic evaluation of the effect of composite formulation on polymerization shrinkage stress.

We compared polymerization stress in two commercial composites and three experimental composites made using camphorquinone (CQ) and/or phenylpropanedione (PPD) as photoinitiators. The internal surfaces of photoelastic resin discs with cylindrical cavities were roughened and treated with adhesive. Composites were divided into five groups: two commercial composites (Filtek Silorane and Filtek Z25...

متن کامل

Effect of Light-curing Units and Activation Mode on Polymerization Shrinkage and Shrinkage Stress of Composite Resins

The aim of this study was to evaluate the polymerization shrinkage and shrinkage stress of composites polymerized with a LED and a quartz tungsten halogen (QTH) light sources. The LED was used in a conventional mode (CM) and the QTH was used in both conventional and pulse-delay modes (PD). The composite resins used were Z100, A110, SureFil and Bisfil 2B (chemical-cured). Composite deformation u...

متن کامل

Polymerization shrinkage, flexural and compression properties of low-shrinkage dental resin composites.

This study evaluated the polymerization shrinkage, flexural and compressive properties of low-shrinkage resin composites. For the study, four methacrylate-based and one silorane-based resin composites were light cured using three different light-curing units (LCUs) and their polymerization shrinkage, flexural (strength (FS) and modulus (FM)) and compressive (strength (CS) and modulus (CM)) prop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Schweizer Monatsschrift fur Zahnmedizin = Revue mensuelle suisse d'odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia

دوره 122 4  شماره 

صفحات  -

تاریخ انتشار 2012