Evaluation of Virtual Refrigerant Mass Flow Sensors

نویسندگان

  • Woohyun Kim
  • James E. Braun
چکیده

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressor that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor suction or discharge valve is leaking and the compressor is not delivering the expected flow, the energy-balance or EEV model can provide accurate flow estimates. In this case, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics, as will be demonstrated in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Detection And Diagnosis For Air Conditioners And Heat Pumps Based On Virtual Sensors

Kim, Woohyun. Ph.D., Purdue University, December 2013. Fault Detection and Diagnosis for Air Conditioners and Heat Pumps based on Virtual Sensors. Major Professor: James E. Braun, School of Mechanical Engineering. The primary goal of this research is to develop and demonstrate an integrated, on-line performance monitoring and diagnostic system with low cost sensors for air conditioning and heat...

متن کامل

Virtual Refrigerant Mass Flow and Power Sensors for Variable-Speed Compressors

The use of variable-speed compressors in heat pumps and air conditioners has increased in recent years in order to improve comfort and energy efficiency. At the same time, there is a trend towards embedding more sensors in this type of equipment to facilitate real-time energy monitoring and diagnostics. Although compressor mass flow rate and power consumption are useful indices for performance ...

متن کامل

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Models for unitary air conditioners and heat pumps typically have difficulties in providing accurate predictions for the following situations: 1) charge modeling over a large range of charge levels, 2) two-phase refrigerant entering fixed-orifice expansion devices, 3) two-phase refrigerant entering compressors, and 4) non-uniform refrigerant mass flow allocation among evaporator circuits at low...

متن کامل

Unsteady State Analysis Of A Hermetic Reciprocating Compressor: Heat Transfer Inside the Cylinder And Valve Dynamics

In this work, an unsteady state analysis of the compression cycle of a small hermetic reciprocating compressor for domestic refrigeration was carried out. The mass and energy balances were applied to the refrigerant inside the cylinder in order to determine the mass and temperature behaviour through the compression process. A specific onedimensional model of the valves was developed to calculat...

متن کامل

Evaluation of a Virtual Refrigerant Charge Sensor

The primary goal of work described in this paper is to evaluate and enhance a virtual refrigerant charge sensor, developed in a previous study. The virtual refrigerant charge sensor algorithm employs low-cost and non-invasive measurements (i.e. surface mounted temperature measurements) to estimate refrigerant charge level for packaged air conditioning systems. It can be embedded within a portab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014