Arterial transit time imaging with flow encoding arterial spin tagging (FEAST).

نویسندگان

  • Jiongjiong Wang
  • David C Alsop
  • Hee Kwon Song
  • Joseph A Maldjian
  • Kathy Tang
  • Alana E Salvucci
  • John A Detre
چکیده

Arterial spin labeling (ASL) perfusion imaging provides direct and absolute measurement of cerebral blood flow (CBF). Arterial transit time is a related physiological parameter reflecting the duration for the labeled spins to reach the brain region of interest. Most of the existing ASL approaches to assess arterial transit time rely on multiple measurements at various postlabeling delay times, and thus are vulnerable to motion artifact as well as computational error. We describe the use of flow encoding arterial spin tagging (FEAST) technique to measure tissue transit time, which can be derived from the ratio between the ASL signals measured with and without appropriate bipolar gradients. In the present study, we provided a theoretical framework and carried out an experimental validation during steady-state imaging. The global mean tissue transit time was approximately 1100 and 1400 ms for two conditions of bipolar gradients with specific encoding velocity (Venc) of 29 and 8 mm/sec, respectively. The mean tissue transit time measured within cerebral vascular territories was shortest in the deep middle cerebral artery (MCA) territory. Application of the FEAST technique in two patients with cerebrovascular disease demonstrated prolonged tissue transit times in the affected vascular territories which were consistent with results from other MR imaging modalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of arterial transit times estimated using FEAST and LL-FAIR

Introduction Arterial transit time is a critical parameter for calculating cerebral blood flow (CBF) using arterial spin labeling (ASL). Arterial transit time is also a novel physiological parameter that is uniquely measured by ASL and may have independent clinical significance for detecting CBF that is maintained through collateral flow sources. Most ASL experiments acquire data at a single de...

متن کامل

Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques.

"Vascular" artifacts can have substantial effects on human cerebral blood flow values calculated by using arterial spin tagging approaches. One vascular artifact arises from the contribution of "tagged" arterial water spins to the observed change in brain water MR signal. This artifact can be reduced if large bipolar gradients are used to "crush" the MR signal from moving arterial water spins. ...

متن کامل

Quantifying CBF with pulsed ASL: technical and pulse sequence factors.

We summarize here current methods for the quantification of CBF using pulsed arterial spin labeling (ASL) methods. Several technical issues related to CBF quantitation are described briefly, including transit delay, signal from larger arteries, radio frequency (RF) slice profiles, magnetization transfer, tagging efficiency, and tagging geometry. Many pulsed tagging schemes have been devised, wh...

متن کامل

Anteroposterior perfusion heterogeneity in human hippocampus measured by arterial spin labeling MRI.

Measurements of blood flow in the human hippocampus are complicated by its relatively small size, unusual anatomy and patterns of blood supply. Only a handful of arterial spin labeling (ASL) MRI articles have reported regional cerebral blood flow (rCBF) values for the human hippocampus. Numerous reports have found heterogeneity in a number of other physiological and biochemical parameters along...

متن کامل

H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans.

Steady-state arterial spin tagging approaches can provide quantitative images of CBF, but have not been validated in humans. The work presented here compared CBF values measured using steady-state arterial spin tagging with CBF values measured in the same group of human subjects using the H(2)(15)O IV bolus PET method. Blood flow values determined by H(2)(15)O PET were corrected for the known e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2003