Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach.
نویسندگان
چکیده
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy (- 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall (- 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.
منابع مشابه
Patient-specific finite element analysis of transcatheter aortic valve implantation
Aortic valve stenosis represents an important public health problem which can be treated through transcatheter aortic valve implantation. Being a quite recent technology, many aspects related to such a minimallyinvasive procedure need further investigation (e.g., paravalvular leakage). The well-established finite element method represents a possible technology to study such aspects within a vir...
متن کاملReconstruction of Stent Induced Loading Forces on the Aortic Valve Complex
In order to evaluate the performance of stents used in transcatheter aortic valve implantation (T-AVI), finite element simulations are set up to reconstruct patient specific contact forces between implant and its surrounding tissue. The reference geometry of the stent is obtained using micro-CT scanning data. A procedure is defined to create a numerically efficient and robust model of the stent...
متن کاملWarning about the Risk of Blood Flow Stagnation after Transcatheter Aortic Valve Implantation
In this work, the hemodynamics in the sinuses of Valsalva after Transcatheter Aortic Valve Implantation is numerically examined. We focus on the physical results in the two-dimensional case. We use a finite element methodology based on a Lagrange multiplier technique that enables to couple the dynamics of blood flow and the leaflets’ movement. A massively parallel implementation of a monolithic...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملImpact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study
Transcatheter aortic valve implantation (TAVI) can treat symptomatic patients with calcific aortic stenosis. However, the severity and distribution of the calcification of valve leaflets can impair the TAVI efficacy. Here we tackle this issue from a biomechanical standpoint, by finite element simulation of a widely adopted balloon-expandable TAVI in three models representing the aortic root wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید