T Dwarfs and the Substellar Mass Function . I . Monte Carlo Simulations
نویسنده
چکیده
Monte Carlo simulations of the field substellar mass function (MF) are presented, based on the latest brown dwarf evolutionary models from Burrows et al. (1997) and Baraffe et al. (2003). Starting from various representations of the MF below 0.1 M⊙ and the stellar birth rate, luminosity functions (LFs) and Teff distributions are produced for comparison with observed samples. These distributions exhibit distinct minima in the mid-type L dwarf regime followed by a rise in number density for fainter/cooler brown dwarfs, predicting many more T-type and cooler brown dwarfs in the field even for relatively shallow mass functions. Deuterium-burning brown dwarfs (0.012 M⊙ ≤ M ≤ 0.075 M⊙) dominate field objects with 400 ≤ Teff ≤ 2000 K, while non-fusing brown dwarfs make up a substantial proportion of field dwarfs with Teff ≤ 500 K. The shape of the substellar LF is fairly consistent for various assumptions of the Galactic birth rate, choice of evolutionary model, and adopted age and mass ranges, particularly for field T dwarfs, which as a population provide the best constraints for the field substellar MF. Exceptions include a depletion of objects with 1200 ≤ Teff ≤ 2000 K in “halo” systems (ages > 9 Gyr), and a substantial increase in the number of very cool brown dwarfs for lower minimum formation masses. Unresolved multiple systems tend to enhance features in the observed LF and may contribute significantly to the space density of very cool brown dwarfs. However, these effects are small (< 10% for Teff . 300 K) for binary fractions typical for brown dwarf systems (10–20%). An analytic approximation to correct the observed space density for unresolved multiple systems in a magnitude-limited survey is derived. As an exercise, surface densities as a function of Teff are computed for shallow near-infrared (e.g., 2MASS) and deep red-optical (e.g., UDF) surveys based on the simulated LFs and empirical absolute magnitude/Teff relations. These calculations indicate that a handful of L and T dwarfs, as well as late-type M and L halo subdwarfs, should be present in the UDF field depending on the underlying MF and disk scale height. These simulations and their dependencies on various factors provide a means for extracting the field substellar MF from observed samples, an issue pursued using 2MASS T dwarf discoveries in Paper II. Subject headings: Galaxy: stellar content — methods: numerical — stars: low mass, brown dwarfs — stars: luminosity function, mass function
منابع مشابه
Energy study at different solvents for potassium Channel Protein by Monte Carlo, Molecular and Langevin Dynamics Simulations
Potassium Channels allow potassium flux and are essential for the generation of electric current acrossexcitable membranes. Potassium Channels are also the targets of various intracellular controlmechanisms; such that the suboptimal regulation of channel function might be related to pathologicalconditions. Realistic studies of ion current in biologic channels present a major challenge for compu...
متن کاملDetectability of Transiting Jupiters and Low-Mass Eclipsing Binaries in Sparsely Sampled Pan-STARRS-1 Survey Data
We present detailed simulations of the Pan-STARRS-1 (PS1) multi-epoch, multiband 3π Survey in order to assess its potential yield of transiting planets and eclipsing binaries. This survey differs from dedicated transit surveys in that it will cover the entire Northern sky but provide only sparsely sampled light curves. Since most eclipses would be detected at only a single epoch, the 3π Survey ...
متن کاملBinaries and the L Dwarf/t Dwarf Transition
High-resolution imaging has revealed an unusually high binary fraction among objects spanning the transition between the L dwarf and T dwarf spectral classes. In an attempt to reproduce and unravel the origins of this apparent binary excess, I present a series of Monte Carlo mass function and multiplicity simulations of field brown dwarfs in the vicinity of the Sun. These simulations are based ...
متن کاملComparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کاملA Large-area Search for Low-mass Objects in Upper Scorpius. Ii. Age and Mass Distributions
We present continued results from a wide-field, 150 deg, optical photometric and spectroscopic survey of the northern part of the 5 Myr old Upper Scorpius OB association. Photometry and spectral types were used to derive effective temperatures and luminosities and place newly identified association members onto a theoretical Hertzsprung-Russell diagram. From our survey, we have discovered 145 n...
متن کامل