Characterization and Correction of Geometric Distortions in 814 Diffusion Weighted Images.
نویسندگان
چکیده
INTRODUCTION Diffusion Weighted Imaging (DWI), which is based on Echo Planar Imaging (EPI) protocols, is becoming increasingly important for neurosurgical applications. However, its use in this context is limited in part by significant spatial distortion inherent to EPI. METHOD We evaluated an efficient algorithm for EPI distortion correction (EPIC) across 814 DWI scans from 250 brain tumor patients and quantified the magnitude of geometric distortion for whole brain and multiple brain regions. RESULTS Evaluation of the algorithm's performance revealed significantly higher mutual information between T1-weighted pre-contrast images and corrected b = 0 images than the uncorrected b = 0 images (p < 0.001). The distortion magnitude across all voxels revealed a median EPI distortion effect of 2.1 mm, ranging from 1.2 mm to 5.9 mm, the 5th and 95th percentile, respectively. Regions adjacent to bone-air interfaces, such as the orbitofrontal cortex, temporal poles, and brain stem, were the regions most severely affected by DWI distortion. CONCLUSION Using EPIC to estimate the degree of distortion in 814 DWI brain tumor images enabled the creation of a topographic atlas of DWI distortion across the brain. The degree of displacement of tumors boundaries in uncorrected images is severe but can be corrected for using EPIC. Our results support the use of distortion correction to ensure accurate and careful application of DWI to neurosurgical practice.
منابع مشابه
Application of K-Space Energy Spectrum Analysis for Inherent and Dynamic B0 Mapping and Distortion Correction in DTI
Introduction Diffusion tensor imaging (DTI) is a powerful technique for the noninvasive characterization of the microstructure of normal and pathological tissue. However, it is typically performed with echo-planar imaging (EPI) and is thus vulnerable to spatial and temporal variations of the static magnetic field (B0) caused by susceptibility effects near air/tissue interfaces, eddy currents in...
متن کاملGeometric distortions of diffusion weighted imaging of the head/neck in combined PET/MR: optimization of image acquisition and post-processing correction for oncology applications
Dept. of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen, Denmark The combination of PET with Diffusion Weighted Imaging (DWI) is a promising application of PET/MR. DWI geometric accuracy can be compromised in body regions with complex anatomy. Here, we assess DWI head/neck image quality following optimization of acquisition and post-processing. Preliminary data from 1...
متن کاملCorrection of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation.
Geometric distortions of echo-planar images produced by the strong eddy currents present in the diffusion tensor imaging experiment are a major confound to the accurate quantification of diffusion coefficients, and measures of diffusion anisotropy based upon them. Here we investigate how the method of iterative cross-correlation (ICC) of baseline and diffusion-weighted images (DWIs) originally ...
متن کاملComparison of EPI Distortion Correction Methods in Diffusion Tensor MRI
Introduction Diffusion weighted images (DWIs) used for Diffusion Tensor (DT) calculation are commonly acquired with Echo-planar imaging (EPI). Unfortunately, EPI is very sensitive to magnetic field (B0 ) inhomogeneities, which result in local geometric distortions in regions close to air-tissue interfaces. These distortions degrade the anatomical accuracy of DT-MRI maps and potentially increase...
متن کاملAccounting for Changes in Signal Variance in Diffusion Weighted Images Following Interpolation for Motion and Distortion Correction
Introduction: Processing of clinical diffusion weighted images (DWIs) for Diffusion Tensor Imaging (DTI) and other applications requires correction for motion, eddy current distortions [1], and susceptibility induced EPI distortions [2]. These corrections are obtained by image registration techniques followed by interpolation of the original images. Image interpolation, however, alters the nois...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- PloS one
دوره 11 3 شماره
صفحات -
تاریخ انتشار 2016