Quantitative analysis of phantom studies of 111In and 68Ga imaging of neuroendocrine tumours
نویسندگان
چکیده
BACKGROUND Nuclear medicine imaging of neuroendocrine tumours is performed either by SPECT/CT imaging, using 111In-octreotide or by PET/CT imaging using 68Ga-radiolabelled somatostatin analogs. These imaging techniques will give different image quality and different detection thresholds for tumours, depending on size and activity uptake. The aim was to evaluate the image quality for 111In-SPECT and 68Ga-PET imaging, i.e. the smallest volume possible to visualize for different source-to-background activity ratios. The accuracy of quantification of lesion volume and activity was also investigated to develop an objective evaluation for radionuclide therapy eligibility. The phantom study was performed using the NEMA IEC Body Phantom with six hot spheres having inner diameters of 10, 13, 17, 22, 28, and 37 mm, filled with either 68Ga or 111In with sphere-to-background ratios (SBRs) of no background activity, 5:1, 2.5:1, and 1.25:1. Activity ratios of 1.25:1 and 2.5:1 are clinically found for lesions close to the liver and spleen. Clinical acquisition and reconstruction protocols were applied. Line profiles were drawn to evaluate the smallest detectable volume within a given SBR. Recovery curves based on threshold-based VOIs, threshold-based VOIs adapted to the background and CT-based ROIs were obtained for all SBRs and sphere diameters, allowing for quantification. RESULTS The 10-mm sphere was not possible to detect in SPECT images. It was detectable in PET images for SBRs of 2.5:1 and higher. In a background corresponding to the activity uptake in the liver, spheres larger than 22-37 mm were detectable in the 111In-SPECT images and spheres larger than 13-22 mm were detectable in the 68Ga-PET images. The maximum activity concentration was accurately quantified for spheres larger than 22 mm in the PET images; however, the quantification was impaired by sphere size and background activity. CONCLUSIONS It was not possible to detect the 10-mm sphere in any of the SPECT images. In a background corresponding to the activity uptake in the liver, spheres larger than approximately 30 mm were visible in the 111In-SPECT images and spheres larger than approximately 17 mm were visible in the 68Ga-PET images. Sphere diameter and background activity strongly affect the possibility of a correct quantification.
منابع مشابه
Preclinical evaluation of 68Ga-DOTA-minigastrin for the detection of cholecystokinin-2/gastrin receptor-positive tumors.
In comparison to somatostatin receptor scintigraphy, gastrin receptor scintigraphy using 111In-DTPA-minigastrin (MG0) showed added value in diagnosing neuroendocrine tumors. We investigated whether the 68Ga-labeled gastrin analogue DOTA-MG0 is suited for positron emission tomography (PET), which could improve image quality. Targeting of cholecystokinin-2 (CCK2)/gastrin receptor-positive tumor c...
متن کاملDiagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors
Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...
متن کاملSomatostatin receptor imaging in patients with neuroendocrine tumors: not only SPECT?
In this issue of The Journal of Nuclear Medicine, Gabriel et al. (1) report their experience with 68Ga-labeled 1,4,7,10tetraazacyclododecane-N,N9,N99,N999tetraacetic acid-D-Phe1-Tyr3-octreotide (68Ga-DOTA-TOC) PET in a series of 84 patients with neuroendocrine tumors (NET). PET was more accurate with a higher detection rate than somatostatin receptor scintigraphy (using 111In-DOTA-TOC or 99mTc-...
متن کاملUse of a Ray-Based Reconstruction Algorithm to Accurately Quantify Preclinical MicroSPECT Images.
This work aimed to measure the in vivo quantification errors obtained when ray-based iterative reconstruction is used in micro-single-photon emission computed tomography (SPECT). This was investigated with an extensive phantom-based evaluation and two typical in vivo studies using 99mTc and 111In, measured on a commercially available cadmium zinc telluride (CZT)-based small-animal scanner. Iter...
متن کاملDevelopment of 111In-labeled porphyrins for SPECT imaging
Objectives: The aim of this research was the development of 111In-labeled porphyrins as possible radiopharmaceuticals for the imaging of tumors. Methods: Ligands, 5, 10, 15, 20-tetrakis (3, 5-dihydroxyphenyl) porphyrin) (TDHPP), 5, 10, 15, 20-tetrakis (4-hydroxyphenyl) porphyrin (THPP) and 5, 10, 15, 20-tetrakis (3,4-dimethoxyphenyl) porphyrin) (TDMPP) were labeled with 111InCl3 (produced from ...
متن کامل