Evaluation of a latex agglutination kit (Virogen Rotatest) for detection of bovine rotavirus in fecal samples.

نویسندگان

  • Y Al-Yousif
  • J Anderson
  • C Chard-Bergstrom
  • A Bustamante
  • M Muenzenberger
  • K Austin
  • S Kapil
چکیده

The performance of the Virogen Rotatest latex agglutination test (LAT) was evaluated for detection of bovine rotavirus antigen. Sixty-three fecal samples from diarrheic calves were collected from November 1999 to May 2000 and screened by LAT, the Rotazyme II enzyme-linked immunosorbent assay (ELISA), and virus isolation (VI) followed by an anti-rotavirus fluorescent-antibody (FA) test to detect the presence of group A rotavirus antigen. Of the 63 samples screened by VI-FA, 33 (58%) tested positive for rotavirus antigen. When the results from the LAT were compared to those from VI-FA, the "gold standard" for detection of bovine rotavirus in fecal samples, the sensitivity and specificity were found to be 87.8 and 73.3%, respectively. Latex agglutination compared with ELISA (the reference method) showed 100% sensitivity and 96.3% specificity, and when ELISA was compared with VI, the sensitivity was 84.8% and the specificity was 73.3%. Latex agglutination is easy to perform in a short time and does not require expensive equipment or skilled personnel, and the reagents have long shelf lives. These factors make the LAT suitable and highly efficient for use in a clinical laboratory as a rapid screening test for bovine rotavirus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of nine commercial immunoassays for the detection of rotavirus in fecal specimens.

One hundred fecal specimens obtained from patients with acute gastroenteritis were tested for rotavirus with nine commercial immunoassays to evaluate the sensitivity, specificity, predictive value, and diagnostic accuracy of these assays. Kits evaluated included two monoclonal antibody-based enzyme immunoassays (EIAs) (Rotaclone and Pathfinder Rotavirus), three polyclonal antibody-based EIAs (R...

متن کامل

Development of a Latex Agglutination Method for Diagnosis of Rotavirus Infections

Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...

متن کامل

Evaluation of seven immunoassays for detection of rotavirus in pediatric stool samples.

The performance of seven commercially manufactured rotavirus assays was evaluated with 144 pediatric stool specimens and compared with electron microscopy (EM) findings. The four enzyme-linked immunosorbent assays used were Rotazyme II, Pathfinder, IDL rotavirus immunoassay, and Enzygnost (Behring) rotavirus assay. The three latex tests were Meritec rotavirus detection test, Virogen Rotatest, a...

متن کامل

Development, evaluation, and application of lateral-flow immunoassay (immunochromatography) for detection of rotavirus in bovine fecal samples.

A lateral-flow immunoassay (LFT) was developed to detect bovine rotavirus in fecal samples. Using samples (n = 74) from diarrheic calves, a comparison of the LFT with a commercial latex agglutination test (LAT) and transmission electron microscopy (EM) was conducted. When EM was used as the reference method, initial studies of 29 samples indicated 70 and 80% sensitivities of the LFT and LAT, re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and diagnostic laboratory immunology

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2001