Microbiological testing of devices used in maintaining peripheral venous catheters 1
نویسندگان
چکیده
Objective: to evaluate the use of peripheral venous catheters based on microbiological analysis of devices (dressing and three-way stopcocks) and thus contribute to the prevention and infection control. Methods: this was a prospective study of microbiological analysis of 30 three-way stopcocks (external surfaces and lumens) and 30 dressing used in maintaining the peripheral venous catheters of hospitalized adult patients. Results: all external surfaces, 40% of lumens, and 86.7% of dressing presented bacterial growth. The main species isolated in the lumen were 50% coagulase-negative Staphylococcus, 14.3% Staphylococcus aureus, and 14.3% Pseudomonas aeruginosa. Fifty nine percent of multidrug-resistant bacteria were isolated of the three-way stopcocks, 42% of the lumens, and 44% of the dressing with a predominance of coagulase-negative Staphylococcus resistant to methicillin. Besides, 18% gram-negative bacteria with resistance to carbapenems were identified from multidrug-resistant bacteria on the external surfaces of the three-way stopcocks. Conclusion: it is important to emphasize the isolation of coagulase-negative Staphylococcus and gram-negative bacteria resistant to methicillin and carbapenems in samples of devices, respectively, which reinforces the importance of nursing care in the maintenance of the biologically safe environment as well as prevention and infection control practices. Objetivo: avaliar o uso de cateteres venosos periféricos com base em análises microbiológicas de dispositivos (curativos e torneiras de três vias - T3Vs) e assim contribuir para a prevenção e controle de infecção. Métodos: estudo prospectivo de análise microbiológica de 30 T3Vs (superfícies externas e lúmens) e 30 curativos utilizados na manutenção dos cateteres venosos periféricos de pacientes adultos hospitalizados. Resultados: todas as superfícies externas, 40% dos lúmens e 86,7% dos curativos apresentaram crescimento bacteriano. As principais espécies isoladas no lúmen foram 50% Staphylococcus coagulase-negativa, 14,3% Staphylococcus aureus e 14,3% Pseudomonas aeruginosa. Cinquenta e nove por cento das bactérias multirresistentes foram isoladas das T3Vs, 42% dos lúmens e 44% dos curativos com predominância de Staphylococcus coagulase-negativa resistente à meticilina. Além disso, 18% das bactérias gram-negativas com resistência aos carbapenêmicos foram identificadas a partir de bactérias multirresistentes nas superfícies externas das T3Vs. Conclusão: é importante enfatizar o isolamento de Staphylococcus coagulase-negativa resistente à meticilina e bactérias gram-negativas resistentes aos carbapenêmicos em amostras de dispositivos, o que reforça a importância do cuidado de enfermagem na manutenção do ambiente biologicamente seguro, assim como práticas de prevenção e controle de infecção. Objetivo: evaluar el uso de catéteres venosos periféricos basado en el análisis microbiológico de dispositivos (vendajes y llaves de tres vías) y así contribuir a la prevención y control de infecciones. Métodos: se trata de un estudio prospectivo de análisis microbiológico de 30 llaves de tres vías (superficies externas y lumen) y 30 apósitos utilizados en el mantenimiento de los catéteres venosos periféricos de pacientes adultos hospitalizados. Resultados: todas las superficies externas, el 40% de los lúmenes y el 86,7% de los vendajes presentaron crecimiento bacteriano. Las principales especies aisladas en el lumen fueron 50% Staphylococcus coagulasa-negativa, 14.3% Staphylococcus aureus, y 14.3% Pseudomonas aeruginosa. Cincuenta y nueve por ciento de las bacterias resistentes a múltiples fármacos fueron aisladas de las llaves de tres vías, el 42% de los lúmenes, y el 44% del apósito con un predominio de Staphylococcus coagulasa-negativa resistente a la meticilina. Además, se identificaron 18% de bacterias gram-negativas con resistencia a carbapenems entre las bacterias multirresistentes en las superficies externas de las llaves de tres vías. Conclusión: es importante enfatizar el aislamiento de Staphylococcus coagulasa-negativa y bacterias gram-negativas resistentes a la meticilina y carbapenem en muestras de dispositivos, respectivamente, lo que refuerza la importancia de la atención de enfermería en el mantenimiento del medio ambiente biológicamente seguro, así como la prevención y las prácticas de control de la infección. assa.
منابع مشابه
ASHP therapeutic position statement on the institutional use of 0.9% sodium chloride injection to maintain patency of peripheral indwelling intermittent infusion devices.
0.9% Sodium chloride injection is a safe and effective indwelling solution for maintaining catheter patency of peripheral indwelling intermittent infusion devices (PIIIDs) in adults and children age one year or older. ASHP supports the use of 0.9% sodium chloride injection in preference to heparin-containing flush solutions (heparin flush) in the institutional setting, on the basis of clinical ...
متن کاملReview of recommendations to prevent and reduce catheter-related bloodstream infections
ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...
متن کاملComplications of Peripheral Venous Access Devices: Prevention, Detection, and Recovery Strategies.
Most hospitalized patients have placement of a peripheral venous access device, either a short peripheral catheter or a peripherally inserted central catheter. Compared with central venous catheters that are not peripherally inserted, the other 2 types are generally perceived by health care providers as safer and less complicated to manage, and less emphasis is placed on the prevention and mana...
متن کاملSurvey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملHeparinized saline versus normal saline for maintaining peripheral venous catheter patency in China: An open-label, randomized controlled study
Objective To evaluate the effects of heparin saline versus normal saline as locking solution for maintaining patency in peripheral venous catheters in Chinese patients. Methods This open-label, randomized controlled study was conducted in two hepatobiliary surgery wards, where patients received identical treatments, at a tertiary referral hospital. Patients were randomly divided into a normal s...
متن کاملAntibiotic–Heparin Lock: In Vitro Confirmation of Antibacterial Activity
Objective: To determine whether high concentrations of antibiotic “locked” into a central venous catheter with heparin would retain sufficient antimicrobial activity to inhibit the growth of organisms commonly causing catheter-related infections in patients undergoing hemodialysis. Methods: Cefazolin, vancomycin, ceftazidime (all at final concentrations of 10 mg/mL), and gentamicin (final conce...
متن کامل