Vascular access surveillance: evaluation of combining dynamic venous pressure and vascular access blood flow measurements.

نویسندگان

  • Heidi Hoeben
  • Ali K Abu-Alfa
  • Robert F Reilly
  • John E Aruny
  • Koenraad Bouman
  • Mark A Perazella
چکیده

BACKGROUND/AIMS Vascular access thrombosis is one of the most morbid problems encountered by hemodialysis patients. Surveillance protocols utilizing venous pressure (Vp) and vascular access blood flow (VABF) measurements have been employed to preserve vascular access. We undertook a study to evaluate combined dynamic Vp and VABF measurements in the identification of vascular access impairment. We also assessed the effect of preventive repair on thrombosis rates in impaired vascular accesses identified by surveillance. METHODS Eighty-six chronic hemodialysis patients with a functioning vascular access were enrolled into the surveillance protocol. All vascular accesses with greater than 50% of monthly Vp readings >120 mm Hg or VABF <500 ml/min in arteriovenous fistulas (AVFs) and VABF <650 ml/min in arteriovenous grafts (AVGs), or a decrease in VABF >25% compared to the highest previously measured value, were considered positive. Stenosis >50% on fistulography or a thrombotic event were defined as a 'vascular access impairment episode' while a stenosis <50% or the absence of a thrombotic event was defined as 'no vascular access impairment episode'. Thrombosis rates and intervention rates were calculated per access year at risk. RESULTS The sensitivity and specificity of the combined surveillance protocol for AVFs were 73.3 and 91%, respectively. In AVGs, they were 68.8 and 87.5%, respectively. The rate of thrombotic events was lower in patients who underwent early repair. The addition of dynamic Vp did not reduce the thrombosis rate any further than surveillance based on VABF alone. CONCLUSION Combined monitoring for surveillance of AVFs improved sensitivity but had little benefit in AVGs over VABF monitoring alone. Raising VABF cutoff levels might increase and improve identification of vascular access risk for thrombosis, but at the expense of lower specificity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vascular access surveillance

Arteriovenous graft (AVG) a. Regular Access Blood Flow (Qa) or Doppler ultrasound stenosis (DUS) screening increases the detection of AVG stenosis compared to dynamic venous pressure (DVP)/clinical examination. (Level II evidence) b. Regular Qa screening with pre-emptive angioplasty does not reduce AVG thrombosis or prolong AVG survival. (Level I & II evidence) c. Whether regular DUS screening ...

متن کامل

Access monitoring is worthwhile and valuable.

During the past several years, a limited number of small clinical trials have questioned the role of surveillance in the management of vascular accesses, since the prolongation of access longevity until replacement was not altered. Although prolongation of access life span is an important endpoint, it is not the only one. Reduction in thrombotic events reduces the risks to the patient resulting...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

Alterations in the vascular β-adrenoceptors of the rabbit knee joint due to acute inflammation

  It has been shown that acute inflammation reduces the effectiveness of sympathetic nerves in the regulation of knee joint blood flow. To investigate the role of vascular β- adrenoceptors in this event, 12 NZW rabbits were maintained anaesthetized by 1 % halothane in N2O/O2, and acute knee joint inflammation was induced by intra-articular injection of 1 ml of 2% carageenan solution 24 hours be...

متن کامل

Determining when to measure vascular access flow …that may not be enough

Vascular access in hemodialysis patients is crucial. Vascular access monitoring to ensure access patency is important for patient survival, quality of life, and blood vessel care. The ultrasound dilution method for measuring access flow is a screening tool to assess access dysfunction. Park et al. [1] performed a single-center prospective study of the variation in access flow during hemodialysi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of nephrology

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2003