Arterial imaging with a new forward-viewing intravascular ultrasound catheter, I. Initial studies.

نویسندگان

  • J L Evans
  • K H Ng
  • M J Vonesh
  • B L Kramer
  • S N Meyers
  • T A Mills
  • B J Kane
  • W N Aldrich
  • Y T Jang
  • P G Yock
چکیده

BACKGROUND Intravascular ultrasound (IVUS) of arteries is limited by the inability of current instruments to visualize beyond the catheter tip. We have developed a prototype 4-mm-diameter forward-viewing IVUS catheter (Cardiovascular Imaging Systems, Sunnyvale, Calif) that has the ability to provide B-mode cross-sectional ultrasound data for a distance of up to 2 cm distal to the catheter tip. METHODS AND RESULTS To study the utility of this device, a 20-MHz forward-viewing IVUS catheter was used to examine 13 arterial segments (5 human femoral arteries, 1 human carotid artery, 7 canine arteries) in vitro and 1 phantom. After imaging, all data were compared with histology (Histo). In all cases, the IVUS catheter provided forward-viewing images corresponding to the arterial geometry and demonstrated vascular landmarks and atherosclerotic lesions. There was a good correlation between Histo-determined luminal diameters (LD) and IVUS-determined diameters for a distance of 14 mm ahead of the catheter tip: IVUS LD = 1.0 Histo LD + 1.3 (r = .87). CONCLUSIONS These preliminary data suggest that a forward-viewing IVUS catheter is feasible, accurate, and useful for evaluation of arterial geometry distal to the catheter tip.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial imaging with a new forward-viewing intravascular ultrasound catheter, II. Three-dimensional reconstruction and display of data.

BACKGROUND Current intravascular ultrasound (IVUS) catheters provide transverse imaging at the level of the ultrasound transducer. This limits imaging to large-diameter segments without critical atherosclerotic narrowings. We have developed a prototype 20-MHz forward-viewing IVUS catheter that provides two-dimensional sector imaging distal to the catheter tip. A present limitation of this techn...

متن کامل

ایمنی، اثربخشی و هزینه اثربخشی فناوری تصویربرداری داخل عروقی در مقایسه با آنژیوگرافی در مداخلات عروق کرونر : ارزیابی سریع فناوری سلامت

Background: Intravascular imaging is a tool to detect coronary artery atherosclerosis which plays the major role in vessel stenosis degree determination and plaque pathology as a supplement of invasive angiography. This study aimed at comparing Intravascular imaging with invasive angiography. Materials and Methods: For retrieving second type studies, PubMed, Cochrane Library and Centre for R...

متن کامل

Intraluminal fluorescence spectroscopy catheter with ultrasound guidance.

We demonstrate the feasibility of a time-resolved fluorescence spectroscopy (TRFS) technique for intraluminal investigation of arterial vessel composition under intravascular ultrasound (IVUS) guidance. A prototype 1.8-mm (5.4 Fr) catheter combining a side-viewing optical fiber (SVOF) and an IVUS catheter was constructed and tested with in vitro vessel phantoms. The prototype catheter can locat...

متن کامل

Two-dimensional intravascular near-infrared fluorescence molecular imaging of inflammation in atherosclerosis and stent-induced vascular injury.

OBJECTIVES This study sought to develop a 2-dimensional (2D) intravascular near-infrared fluorescence (NIRF) imaging strategy for investigation of arterial inflammation in coronary-sized vessels. BACKGROUND Molecular imaging of arterial inflammation could provide new insights into the pathogenesis of acute myocardial infarction stemming from coronary atheromata and implanted stents. Presently...

متن کامل

Intravascular ultrasound. Research technique or clinical tool?

I ntravascular ultrasound is a new technique that allows intraluminal catheter-based vascular imaging. Technological advances in miniaturization have produced 4F to 8F catheters that can be safely maneuvered within coronary and peripheral arteries.1,2 Images obtained provide accurate measurements of lumen area as well as high-resolution images of arterial wall components.3,4 Histopathological s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 89 2  شماره 

صفحات  -

تاریخ انتشار 1994