Characterization, quantification, and replication of human sinus bone for surgery simulation phantoms.
نویسندگان
چکیده
The requirement for artificial but realistic, tactile, anatomical models for surgical practice in medical simulation is increasingly evident and shows potential for greater efficiency and availability, and lower costs. Anatomically correct, detailed models with the physical surgical characteristics of real tissue, combined with the ability to reproduce one-off cases, would provide an invaluable tool in the development of surgery. This research work investigates the capture of geometrical and physical data from the human sinus to subsequently direct the production and optimization of such simulation phantoms. Micro-computed tomography analysis of the entire sinus was performed to characterize the sinus complex geometry. Following an extensive review, specialized mechanical testing apparatus and methods relevant to the surgical methods employed were designed and produced. This provided comparative analysis methods for both biological and artificial phantom materials and allowed the optimization of phantom materials with respect to the derived target values.
منابع مشابه
Platelet-rich plasma as filling material in open sinus lift surgery
Background Many biomaterials are used during the open sinus lift surgery, beneath the elevated scheniderian membrane and maxillary sinus bony floor but the search for Ideal material continues. Methods In the maxillary posterior atrophic ridges with the bone height less than four millimeters the open sinus lift surgery performed. The autologous Platelet-rich plasma (PRF) was used as the sol...
متن کاملOutcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial
Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...
متن کاملComparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts
Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...
متن کاملبررسی دقت توموگرافی خطی در تعیین محل حفره بینی و سینوس ماگزیلاری1
Background and Aim: Accurate measurement of bone height and width is essential prior to dental implant placement. The method of surgery as well as, the type and size of implants are determined according to dimensions of the residual bone. The purpose of this study was to evaluate the accuracy of linear tomography in localization of the floor of nasal fossa and maxillary sinus, and to determine ...
متن کاملIntroducing a bony composite as tissue equivalent for radiotherapy phantoms
The use of a device that simulates the actual condition, as well as being equivalent to the human body in materials and tissues, and having the capability of acting like internal motions of human body is necessary to investigate and simulate the motion of a tumor in radiotherapy and to evaluate dosimetrical coverage of the dynamic target. This device which is called the dynamic phantom should s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 223 7 شماره
صفحات -
تاریخ انتشار 2009