Complication Rate and Pitfalls of Temporary Bridging External Fixator in Periarticular Communited Fractures

نویسندگان

  • Jong-Keon Oh
  • Jin-Ho Hwang
  • Dipit Sahu
  • Seung-Hyub Jun
چکیده

BACKGROUND A second staged operation using temporary bridging external fixation (TBEF) has been widely used in patients with periarticular complex fracture, yet few papers have been published on the related complications. The purpose of this study was to report the complication rate and pitfalls directly related to TBEF through a retrospective study and to suggest some solutions. METHODS Fifty-nine cases that were treated by using TBEF were studied among 195 periarticular complex fractures. We retrospectively collected the clinical and radiological data and then the study data was evaluated for 1) cases with unsatisfactory restoration of length, 2) cases with deep infection caused by half pins invading the zone of definitive fixation, and 3) neurovascular injuries related to half pins. RESULTS Complications were observed in 7/59 cases (11%). Problems related to the achievement of length were observed in one case of distal tibia fracture and 2 cases of distal femur fracture. Half pin related infection was observed in 2 cases of distal femur fracture. Neurovascular injury (medial calcaneal nerve injury in a distal tibia fracture) was observed in 2 cases. Among 7 complications, four were related to using TBEF in distal femur fracture. This is because the abundant leg muscles have strong deforming force and infection might be increased due to frequent irritation by the half pins. CONCLUSIONS TBEF is a simple procedure with several advantages. However, complications might be observed if certain principles are not followed. It is thought that many complications due to TBEF can be reduced if the half pins are not inserted in the zone of injury, restoration of length is fully achieved and the neurovascular characteristics are carefully considered. In particular, much more caution is needed in the distal femur, which has abundant muscles surrounding it.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails

  Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...

متن کامل

Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.

OBJECTIVE To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN Standardized proximal tibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the fo...

متن کامل

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Nonbridging external fixation for fractures of the distal radius.

OBJECTIVE To assess the feasibility of using standard components from the small AO external fixator set to support fractures of the distal radius with a construct incorporating distal fixation in the periarticular radius fragment that would allow for primary mobilization of the wrist joint during fracture healing. METHODS In a prospective pilot study of a nonbridging external fixator in early...

متن کامل

Dynamic and static external fixation for distal radius fractures--a systematic review.

INTRODUCTION External fixation of distal radius fractures may be static (wrist-bridging) or dynamic (wrist-bridging with mobile hinge or non-bridging). The aim of this systematic review is to investigate the effectiveness of different methods of external fixation for unstable distal radius fractures. METHODS A Medline database search was performed with strict eligibility criteria to obtain th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2011