Macular pigment measurement by heterochromatic flicker photometry in older subjects: the carotenoids and age-related eye disease study.

نویسندگان

  • D Max Snodderly
  • Julie A Mares
  • Billy R Wooten
  • Lisa Oxton
  • Michael Gruber
  • Tara Ficek
چکیده

PURPOSE To develop a standardized protocol for measuring macular pigment optical density (MPOD) of experimentally naïve subjects by heterochromatic flicker photometry (HFP). METHODS MPOD in eyes of 54 women, age 50 and 79 years (mean, 66), was studied. The spatial profile of MPOD was measured in the right eye, and two spatial points were also measured in the left eye. Forty-eight of these inexperienced subjects completed the protocol on two separate visits. For a subset of the group, the MPOD at two different wavelengths was measured. RESULTS The test-retest correlation at 0.5 degrees eccentricity in the right eye was 0.9. On the second visit, more than 90% of the subjects were able to perform the HFP test with results that were consistent with the absorption spectrum of macular pigment. On the first visit, data from the inexperienced subjects deviated more from the expected relationships between the two wavelengths, presumably because they had less skill in performing the task. However, subjects with high or low macular pigment density were distinguished clearly. CONCLUSIONS Reliable and meaningful measurements of macular pigment density in older subjects can be made using HFP, with a standardized protocol in the limited time available in large epidemiologic studies. This protocol will be made freely available to other researchers on request.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration.

PURPOSE We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD). METHODS Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitome...

متن کامل

A portable instrument for measuring macular pigment with central fixation.

PURPOSE To evaluate the reliability and validity of a portable instrument for measuring macular pigment optical density. METHODS The instrument is small, uses light emitting diodes as light sources and the principles of heterochromatic flicker photometry of comparing foveal and extra-foveal minimum flicker matches. It uses central fixation for the extra-foveal matches, which subjects found ea...

متن کامل

Risk factors for age-related maculopathy are associated with a relative lack of macular pigment.

Macular pigment (MP) is composed of the two dietary carotenoids lutein (L) and zeaxanthin (Z), and is believed to protect against age-related maculopathy (ARM). This study was undertaken to investigate MP optical density with respect to risk factors for ARM, in 828 healthy subjects from an Irish population. MP optical density was measured psychophysically using heterochromatic flicker photometr...

متن کامل

The utility of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment in patients with age-related macular degeneration.

The purpose of this study was to assess the utility and validity of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment optical density (MPOD) in patients with intermediate stages of age-related macular degeneration (AMD). The measurement procedure was optimized to accommodate individual differences in temporal vision related to age, disease, or other factors. ...

متن کامل

Light exposure and macular pigment optical density.

PURPOSE Biochemical research has demonstrated that lutein and zeaxanthin, the two macular carotenoids, are bleachable pigments. Further, evidence suggests that exposure to UV light can degrade plasma carotenoid levels in vivo. The present study investigated the effects of exposure to normal levels of light on the levels of lutein and zeaxanthin in the retina. METHODS The optical density of ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2004