Otoacoustic emissions from normal-hearing and hearing-impaired subjects: distortion product responses.

نویسندگان

  • M P Gorga
  • S T Neely
  • B Bergman
  • K L Beauchaine
  • J R Kaminski
  • J Peters
  • W Jesteadt
چکیده

Distortion product otoacoustic emissions (DPOAE) were measured in normal-hearing and hearing-impaired human subjects. Analyses based on decision theory were used to evaluate DPOAE test performance. Specifically, relative operating characteristic (ROC) curves were constructed and the areas under these curves were used to estimate the extent to which normal and impaired ears could be correctly identified by these measures. DPOAE amplitude and DPOAE/noise measurements were able to distinguish between normal and impaired subjects at 4000, 8000, and, to a lesser extent, at 2000 Hz. The ability of these measures to distinguish between groups decreased, however, as frequency and audiometric criterion used to separate normal and hearing-impaired ears decreased. At 500 Hz, performance was no better than chance, regardless of the audiometric criterion for normal hearing. Cumulative distributions of misses (hearing-impaired ears incorrectly identified as normal hearing) and false alarms (normal-hearing ears identified as hearing impaired) were constructed and used to evaluate test performance for a range of hit rates (i.e., the percentage of correctly identified hearing-impaired ears). Depending on the desired hit rate, criterion values of -5 to -12 dB SPL for DPOAE amplitudes and 8 to 15 dB for DPOAE/noise accurately distinguished normal-hearing ears from those with thresholds greater than 20 dB HL for the two frequencies at which performance was best (4000 and 8000 Hz). It would appear that DPOAE measurements can be used to accurately identify the presence of high-frequency hearing loss, but are not accurate predictors of hearing status at lower frequencies, at least for the conditions of the present measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing

Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...

متن کامل

Distortion-product otoacoustic emissions at ultra-high frequencies in parents of individuals with autosomal recessive hearing loss.

PURPOSE To evaluate the cochlear function of parents of individuals with autosomal recessive gene Gap Junction Protein Beta-2 hearing loss by ultra-high frequencies distortion-product otoacoustic emissions (DPOAEs), compared with responses of a control group matched for age and gender. METHODS We studied 56 subjects aged from 20 to 58 years, divided into two groups. The study group comprised ...

متن کامل

Input-output functions of the nonlinear-distortion component of distortion-product otoacoustic emissions in normal and hearing-impaired human earsa)

Distortion-product otoacoustic emissions (DPOAEs) arise in the cochlea in response to two tones with frequencies f1 and f2 and mainly consist of two components, a nonlinear-distortion and a coherent-reflection component. Wave interference between these components limits the accuracy of DPOAEs when evaluating the function of the cochlea with conventional continuous stimulus tones. Here, DPOAE co...

متن کامل

Distortion product otoacoustic emission suppression tuning curves in normal-hearing and hearing-impaired human ears.

Distortion product otoacoustic emission (DPOAE) suppression measurements were made in 20 subjects with normal hearing and 21 subjects with mild-to-moderate hearing loss. The probe consisted of two primary tones (f2, f1), with f2 held constant at 4 kHz and f2/f1 = 1.22. Primary levels (L1, L2) were set according to the equation L1 = 0.4 L2 + 39 dB [Kummer et al., J. Acoust. Soc. Am. 103, 3431-34...

متن کامل

Otoacoustic Emission in Tinnitus Patients

The purpose of the study was to determine the effect of tinnitus and total effect of tinnitus and the hearing loss function on the distortion product otoacoustic emission. Tinnitus patients were selected to exhibit normal hearing and such tinnitus patients who exhibited the increasing or notch-like sensorineural hearing loss. It was found that the cochlear hearing activity expressed in terms of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 93 4 Pt 1  شماره 

صفحات  -