Strain of bone-implant interface and insertion torque regarding different miniscrew thread designs using an artificial bone model.

نویسندگان

  • Jung-Yul Cha
  • Chung-Ju Hwang
  • Sung Hwang Kwon
  • Han-Sung Jung
  • Kwang-Mahn Kim
  • Hyung Seog Yu
چکیده

OBJECTIVES To evaluate the initial stability of dual-thread miniscrews by analyzing the strain at the bone-implant interface and insertion torque during implantation in artificial bone models with different cortical bone thicknesses. MATERIALS AND METHODS Insertion torque, and strain, measured with a five-element strain gauge in 1.0, 1.5, and 2.0-mm artificial cortical bone, during insertion of single- (OAS-T1507) and dual-thread (MPlant-U3) type self-drilling miniscrews were assessed. RESULTS Both dual- and single-thread miniscrews showed greater than 7790 μstrain for all cortical bone thicknesses, and dual-thread miniscrews reached up to 19580 μstrain in 2.00 m m cortical bone. The strain of dual-thread miniscrews increased with increasing cortical bone thicknesses of 1.0-2.0mm. For single-thread miniscrews, the maximum insertion torque was relatively constant, but maximum insertion torque increased significantly in dual-thread groups with increasing cortical bone thicknesses (P < 0.0001). The maximum insertion torque with all cortical bone thicknesses was significantly lower with single- than dual-thread types (P < 0.0001). CONCLUSIONS Self-drilling dual-thread miniscrews provide better initial mechanical stability, but may cause strain over the physiological bone remodelling limit at the bone-implant interface in thick cortical bone layers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of implant design on primary stability using torque-time curves in artificial bone

BACKGROUND Primary stability following implant placement is essential for osseointegration and is affected by both implant design and bone density. The aim of this study was to compare the relationships between torque-time curves and implant designs in a poor bone quality model. METHODS Nine implant designs, with five implants in each category, were compared. A total of 90 implants (Straumann...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Development and application of a direct method to observe the implant/bone interface using simulated bone

BACKGROUND Primary stability after implant placement is essential for osseointegration. It is important to understand the bone/implant interface for analyzing the influence of implant design on primary stability. In this study rigid polyurethane foam is used as artificial bone to evaluate the bone-implant interface and to identify where the torque is being generated during placement. METHODS ...

متن کامل

Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements

Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the ...

متن کامل

Drilling dimension effects in early stages of osseointegration and implant stability in a canine model

BACKGROUND This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. STUDY DESIGN Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2015