Laser differential confocal radius measurement system.

نویسندگان

  • Ruoduan Sun
  • Lirong Qiu
  • Jiamiao Yang
  • Weiqian Zhao
چکیده

A laser differential confocal radius measurement system with high measurement accuracy is developed for optical manufacturing and metrology. The system uses the zero-crossing point of the differential confocal intensity curve to precisely identify the cat's-eye and confocal positions and uses an interferometer to measure the distance between these two positions, thereby achieving a high-precision measurement for the radius of curvature. The coaxial measuring optical path reduces the Abbe error, and the air-bearing slider reduces the motion error. The error analysis indicates the theoretical accuracy of the system is up to 2 ppm, and the experiment shows that the system has high focusing sensitivity and is little affected by environmental fluctuations; the measuring repeatability is between 4 and 12 ppm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser differential confocal radius measurement.

A new laser differential confocal radius measurement (DCRM) is proposed for high precision measurement of radius. Based on the property of an axial intensity curve that the absolute zero precisely corresponds to the focus of the objective in a differential confocal system (DCS), DCRM uses the zero point of the DCS axial intensity curve to precisely identify the cat's-eye and confocal positions ...

متن کامل

Measuring Method of Radius of Curvature Based on Dual-Frequency Laser Interferometer

In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferometer based on cat’s eye and confocal method. Through analyzing the error source models of radius of curvature testing, optical configuration of the testing device has been optimized...

متن کامل

Laser differential reflection-confocal focal-length measurement.

A new laser differential reflection-confocal focal-length measurement (DRCFM) method is proposed for the high-accuracy measurement of the lens focal length. DRCFM uses weak light reflected from the lens last surface to determine the vertex position of this surface. Differential confocal technology is then used to identify precisely the lens focus and vertex of the lens last surface, thereby ena...

متن کامل

Laser differential confocal lens refractive index measurement.

A new laser differential confocal lens refractive index measurement is proposed, which uses the absolute zero of the differential confocal axial intensity curve to precisely identify the positions of the objective when the measurement pencil is focused on the vertex of the test lens and the reflector with or without the test lens in the measurement light-path, and then uses aberration compensat...

متن کامل

Laser divided-aperture differential confocal sensing technology with improved axial resolution.

In this study, we found that the axial response curve of divided-aperture confocal microscopy has a shift while the point detector has a transverse offset from the optical axis. Based on this, a novel laser divided-aperture differential confocal sensing technology (LDDCST) with absolute zero and high axial resolution, as well as an LDDCST-based sensor, is proposed. LDDCST sets two micro-regions...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 51 26  شماره 

صفحات  -

تاریخ انتشار 2012